Chapter 3 Troubleshooting
Diagnosing Problems
Verify Switch Module Connections
Review this section when troubleshooting switch module connection problems.
Bad or Damaged Cable
Always evaluate the cable for marginal damage or failure. A cable might be just good enough to connect at the physical layer, but it could corrupt packets as a result of subtle damage to the wiring or connectors. You can identify this situation because the port has many packet errors or the port constantly flaps (loses and regains link). You should:
•Inspect or exchange the copper or
•Look for broken or missing pins on cable connectors.
•Rule out any bad patch panel connections or media convertors between the source and destination. If possible, bypass the patch panel or eliminate faulty media convertors
•Try the cable in another port or interface, if possible, to see if the problem follows the cable.
•StackWise Plus cable: remove and inspect the cable and StackWise Plus port for bent pins or damaged connectors. If the StackWise Plus cable is bad, replace it with a known good cable.
Ethernet and Fiber Cables
Make sure that you have the correct cable type for the connection:
•For Ethernet, use Category 3 copper cable for 10 Mb/s UTP connections. Use Category 5, Category 5e, or Category 6 UTP for 10/100 or 10/100/1000 Mb/s connections.
•For
•For copper connections, determine if a crossover cable was used when a
Link Status
Verify that both sides have link. A single broken wire or one shutdown port can cause one side to show link, but the other side does not have link.
A link LED does not guarantee that the cable is fully functional. The cable might have encountered physical stress that causes it to function at a marginal level. If the link light for the port does not come on:
•Connect the cable from the switch module to a known good device.
•Make sure that both ends of the cable are connected to the correct ports.
•Verify that both devices have power.
•Verify that you are using the correct cable type. See Appendix B, “Connector and Cable Specifications” for more information.
•Look for loose connections. Sometimes a cable appears to be seated, but is not. Disconnect the cable, and then reconnect it.
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
|
| |
|