5.7. EQ Settings
Perform EQ settings (ON/OFF, Band number, Gain, Q and Center frequency) of the input/output channels. 9000Series Amplifier responds with the same data as that received. Band number, Gain, Q, and Center frequency cannot be received when EQ is set to OFF. They can be valid only when EQ is set to ON.
Note: Command cannot be received during power off.
A1H, 07H, <Channel Attribute>, <Channel Number>, <OFF/ON>, <Band Number>, <Gain Value>, <Q Value>, <Freq Value>
<Channel Attribute>
00H: Input channel
01H: Output channel
<Channel Number>
00H - 07H (Input channel 1 - 8)
00H - 07H (Output channel 1 - 8)
<OFF/ON> 00H: EQ OFF
01H: EQ ON
<Filter Number>
00H - 09H: Filter 01 - 10
<Gain Value>
EQ-GAIN TABLE
Value | Gain (dB) | Value | Gain (dB) | ||
HEX | DEC |
| HEX | DEC |
|
00H | 0 | 0DH | 13 | +1 | |
01H | 1 | 0EH | 14 | +2 | |
02H | 2 | 0FH | 15 | +3 | |
03H | 3 | 10H | 16 | +4 | |
04H | 4 | 11H | 17 | +5 | |
05H | 5 | 12H | 18 | +6 | |
06H | 6 | 13H | 19 | +7 | |
07H | 7 | 14H | 20 | +8 | |
08H | 8 | 15H | 21 | +9 | |
09H | 9 | 16H | 22 | +10 | |
0AH | 10 | 17H | 23 | +11 | |
0BH | 11 | 18H | 24 | +12 | |
0CH | 12 | 0 |
|
|
|
Note: If testing using Hyperterminal HEX value 0DH may incorrectly translate and will not work. But when used in other applications using the HEX 0DH will work.