Section 3 Software Operations
QUANTUM
3.6 Meters (cont.)
Limiter
The limiter’s threshold meter works on the same principle. When the signal is under the thresh- old setting, the signal is not being processed by the limiter section. The next part of the thresh- old meter is the “o”. It represents the OverEasy® range of compression. When the signal exceeds the threshold set in the limiter section, the plus (+) sign will darken, and gain reduc- tion will begin to occur as a result of the signal exceeding the limiter’s threshold.
Gate / Expander
When the signal is under the threshold set in the gate section, the gate is “closed”, or signal is being attenuated. When the signal is under the threshold, the minus
De-Esser
The
3.7 Monitor Outputs
Monitoring separate bands is a useful and easily accomplished function in the QUANTUM. By pressing the METER/MONITOR button twice you are able to access the monitor selection page. Use the DATA WHEEL to select at which point you would like to monitor. The headphone graphic and arrow change to show the point in the signal chain you are monitoring. The text under “Monitor Out” shows which band and position you are currently selecting. This is a very important option. As you are adjusting dynamic processing within individual bands it helps to monitor the changes made to those bands. “Band 1 pre” monitor position is located just after the crossover, before the gate, compressor, and limiter. “Band 1 post” is located after the gate, compressor, and limiter, before the Normalizer and output. The other bands
®
28 | QUANTUM User Manual |
|
|