Akai EWI5000 manual

Page 28

CC (Continuous Controller): The Hold Button will send a MIDI Continuous Controller (CC) message. If you select this, press the Trans Button to set additional message parameters:

oCn (Controller Number): This is the CC number that will be sent when you press the Hold Button. Use the Hold Button or Interval Button to set the CC number (01127; values over 99 will be shown as the last two digits with a dot between them). Match this number to the CC number of the parameter you want to control.

odU (Data-Up):The value that will be sent with the CC message when you release the Hold Button. Use the Hold Button or Interval Button to set the value (00127; values over 99 will be shown as the last two digits with a dot between them).

odP (Data-Press):The value that will be sent with the CC message when you press the Hold Button. Use the Hold Button or Interval Button to set the value (00127; values over 99 will be shown as the last two digits with a dot between them).

oLA (Latching): This determines if the Hold Button acts as a latching control or momentary control. If you select this, press and hold the Trans Button to set additional message parameters:

OF (Off): When you press and hold the Hold Button, the Data-Press value will be sent. When you release the Hold Button, the Data-Up value will be sent.

on (On): When you press the Hold Button, the Data-Press value will be sent. When you press the Hold Button again, the Data-Up value will be sent.

4.To return to Performance Mode, press the Setup Button until the display is blank.

28

Image 28
Contents User Guide Table of Contents EWI About the EWI5000 SupportPower the EWI5000 Hold the EWI5000 ProperlyTo play EWI5000s audio wirelessly ConnectTo play EWI5000s audio through headphones To play EWI5000 as a wired Midi controllerTips PlayGlide Plate Standard Pitch Pitch-Bend Up Pitch-Bend Down Features Page Page Adjusting Sound Parameters FilterBreath BiteReverb FineChorus Adjusting Sensors To adjust the Note DelayTo adjust the breath sensor Breath SensorPage To adjust the bite sensor Bite SensorPage To adjust the pitch-bend plates Pitch-Bend PlatesGlide Plate To set the function of the glide platePage Calibrating Sensors Key Delay Note Keys and Program ButtonTo calibrate the note keys and Program Button To calibrate the breath sensor To calibrate the glide plate To calibrate the pitch-bend plates Midi Channel Assigning ControlsTo set the Midi Channel Hold Button Off The Hold Button will be disabledTo set the function of the Hold Button Page Interval Button To set the function of the Interval ButtonPage Managing Programs Using the Program ButtonSelecting Programs Using the Note Keys Using the Hold Button and/or Interval ButtonRelease the Program Button Saving Programs An External Midi Sound Module or SoftwareTo save a Program Reverb Using Effects FXTo edit the Reverb effect Delay To edit the Delay effectChorus To edit the Chorus effectTo select a fingering mode Fingering ModesTo update the EWI5000s software Restoring Default SettingsUpdating the Firmware Fingering Charts K1 K2 K3 K4 K5 K6 K10 K11 K12EWI Saxophone Flute Oboe EVI EVI ReversedSetup Mode Menu StructuresMenus Values Menus Values FX Effects Technical Specifications Trademarks and LicensesAkaipro.com