Siemens 505-2557 installation and operation guide 17 I/O Register Quick Reference

Page 57

3.7I/O Register Quick Reference

Figure 3-17 I/O Register Quick Reference

SIMATIC 505±2557 Installation and Operation Guide

Advanced Function Programming 3-27

Image 57
Contents Simatic Copyright 1998 by Siemens Energy & Automation, Inc Manual Publication History List of Effective Pages Contents Iv Contents List of Figures List of Tables Preface European Agency ApprovalsCommunity CE Approval100 Ohm, 10 Ohm, 120 Ohm RTDs, or Millivolt Inputs DescriptionOperating Modes Word Input to the PLC from the Module Scale Units RTD Input to Digital ConversionSignals EffectOut-of-Range Input Effect of Voltage Input 10 Ohm Copper Input Resolution ResolutionInstalling and Configuring the Module Calculating the I/O Base Power BudgetSelecting 2 and 3 Wire or 4 Wire Operation Installing and Configuring the Module Configuring Temperature or SelectingMillivolt Input Celsius or Selecting DegreesFahrenheit Selecting DataConfiguration Jumper Locations Inserting Module IntoBase Copper Wire Table at 25 Degrees Celsius Wiring the Input ConnectorsPress In Wiring Connector Wiring Diagram for 2, 3, or 4 Wire RTD Wiring Diagram for Millivolt Measurements Cable Grounding Example I/O Configuration Chart Advanced Function Programming Introduction Advanced Software FunctionsOverview AdvancedSetting the Module ConfigurationJumper Logging Controller I/OMemory Input and Output Register Offsets Internal Register StructuresInput Registers Input Channel DataPeak/Valley Hold Input Words Input Flag BitsAveraging Output Data RegistersFunction Enable Bits Control RegistersInputs Discrete Handshake Inputs Data Identification Bits OutputsData Loading Process Loading Data into the Simatic 505±2557 ModuleSample Low and High Alarm Setpoints Identifying the Data Being Transferred 11 Enabling the Functions Loaded Loading Programs into the I/O Module 13 Startup Relay Ladder Logic Page Timing Overhead for Functions Enabled When UsingTiming Considerations Timing ConstraintsDefault Function Values Default ValuesDefault Function Values for Simatic 505±2557 Additional Information about Each FunctionDegrees Alarm SetpointsCentigrade or Degrees FahrenheitDigital Filtering Averaging Peak and ValleyHold Flag Bits Hold Reset Precedence FunctionTroubleshooting Symptom Probable Cause Corrective Action 10 Troubleshooting Flow Diagram17 I/O Register Quick Reference I/O Register Quick ReferenceOr K Memory Configuration Tables Page Addressing Worksheet 18 Open RTD Status Bits Items Unique to the Simatic 505±2557 ModuleTroubleshooting Table B-1 Specifications SpecificationsSpecifications subject to change without notice Jumper Settings Log Sheet Customer Response Business Reply Mail