Siemens 505-2557 installation and operation guide Identifying the Data Being Transferred

Page 43

3.The data identification outputs Y19 ± Y17 are set according to the data being transferred. These are decoded by the module in order to distinguish the type of data being loaded (see Figure 3-9).

 

MWIR

 

 

 

 

A V300

 

 

 

C1

B Y17

V300=2

C2

N=3

 

Specified word

 

 

LSB

 

 

14

15

16

 

 

 

 

17

 

 

 

 

18

 

 

 

 

19

Figure 3-9 Identifying the Data Being Transferred

4.Y32 Data_Ready is energized to transfer the word data into the module (see Figure 3-10).

C2Y32

Data_Ready

Figure 3-10 The Data_Ready Bit

SIMATIC 505±2557 Installation and Operation Guide

Advanced Function Programming 3-13

Image 43
Contents Simatic Copyright 1998 by Siemens Energy & Automation, Inc Manual Publication History List of Effective Pages Contents Iv Contents List of Figures List of Tables Preface Approval Agency ApprovalsEuropean Community CE100 Ohm, 10 Ohm, 120 Ohm RTDs, or Millivolt Inputs DescriptionOperating Modes Word Input to the PLC from the Module Scale Units RTD Input to Digital ConversionEffect SignalsOut-of-Range Input Effect of Voltage Input 10 Ohm Copper Input Resolution ResolutionCalculating the I/O Base Power Budget Installing and Configuring the ModuleSelecting 2 and 3 Wire or 4 Wire Operation Installing and Configuring the Module Configuring Selecting Temperature orMillivolt Input Selecting Data Selecting DegreesCelsius or FahrenheitConfiguration Jumper Locations Module Into InsertingBase Copper Wire Table at 25 Degrees Celsius Wiring the Input ConnectorsPress In Wiring Connector Wiring Diagram for 2, 3, or 4 Wire RTD Wiring Diagram for Millivolt Measurements Cable Grounding Example I/O Configuration Chart Advanced Function Programming Advanced Advanced Software FunctionsIntroduction OverviewConfiguration Setting the ModuleJumper Controller I/O LoggingMemory Input Channel Data Internal Register StructuresInput and Output Register Offsets Input RegistersPeak/Valley Hold Input Words Input Flag BitsAveraging Output Data RegistersControl Registers Function Enable BitsInputs Discrete Handshake Inputs Data Identification Bits OutputsData Loading Process Loading Data into the Simatic 505±2557 ModuleSample Low and High Alarm Setpoints Identifying the Data Being Transferred 11 Enabling the Functions Loaded Loading Programs into the I/O Module 13 Startup Relay Ladder Logic Page Timing Constraints When UsingTiming Overhead for Functions Enabled Timing ConsiderationsAdditional Information about Each Function Default ValuesDefault Function Values Default Function Values for Simatic 505±2557Degrees Fahrenheit Alarm SetpointsDegrees Centigrade orDigital Filtering Peak and Valley AveragingHold Flag Bits Hold ResetPrecedence FunctionTroubleshooting Symptom Probable Cause Corrective Action 10 Troubleshooting Flow Diagram17 I/O Register Quick Reference I/O Register Quick ReferenceOr K Memory Configuration Tables Page Addressing Worksheet 18 Open RTD Status Bits Items Unique to the Simatic 505±2557 ModuleTroubleshooting Table B-1 Specifications SpecificationsSpecifications subject to change without notice Jumper Settings Log Sheet Customer Response Business Reply Mail