Siemens 505-2557 installation and operation guide Table B-1 Specifications

Page 63

 

 

 

Appendix B

 

 

 

Specifications

 

 

 

 

 

Table B-1 Specifications

 

 

 

Input Channels

 

16 RTD or Millivolt Inputs

 

 

(2 inputs per channel group)

 

 

 

RTD Types

 

10W Cu (TCR=0.00427 W/W/_C)

 

 

100W Pt (TCR=0.003850 W/W/_C)

 

 

European DIN 43760

 

 

120W Ni (TCR=0.00672 W/W/_C)

 

 

2, 3, and 4 wire modes

 

 

 

 

 

RTD Excitation Current

 

250 micro Amp

 

 

 

 

 

 

 

Millivolt Input Range

 

0 to 100 mV

 

 

 

 

 

Millivolt Input Impedance

 

>10KW @ 60 Hz

 

 

>1000MW @ DC

 

 

 

Absolute Millivolt Accuracy

 

±0.5% full scale or ±500 mV

 

 

 

Lead Compensation

 

20W per lead wire

 

 

 

Input Overrange Protection

 

30 VDC or VAC continuous

 

 

 

 

Measurement Ranges

 

10W Cu

±100_C to 260_C (±148_F to 500_F)

 

 

100W Pt

±200_C to 850_C (±328_F to 1562_F)

 

 

120W Ni

±80_C to 260_C (±112_F to 500_F)

 

 

 

 

 

ADC Resolution

 

16 Bits

 

 

 

 

 

Data Presentation

 

Measurement returned in 0.2 degree resolution as tem-

 

 

perature X10 or as an integer (0±32000).

 

 

(16WX mode). Data word includes sign bit and

 

 

overrange/underrange bit. Millivolts returned as milli-

 

 

volts X100. (16WX mode). 0.1 degree in

 

 

Advanced Mode.

 

 

 

Measurement Units

 

Degrees C or F selectable by module

 

 

 

Digital Filtering Time Constant

 

80 mSec (16 WX mode)

 

 

 

Update Time (all 16 channels)

 

18 mSec no filtering

 

 

20 mSec digital filtering enabled

 

 

48 mSec advanced functions enabled

 

 

 

Repeatability

 

±0.2_C or _F all RTD types (16 WX mode)

 

 

±0.1_C or _F all RTD types (advanced mode)

 

 

 

 

 

SIMATIC 505±2557 Installation and Operation Guide

Specifications

B-1

Image 63
Contents Simatic Copyright 1998 by Siemens Energy & Automation, Inc Manual Publication History List of Effective Pages Contents Iv Contents List of Figures List of Tables Preface Approval Agency ApprovalsEuropean Community CE100 Ohm, 10 Ohm, 120 Ohm RTDs, or Millivolt Inputs DescriptionOperating Modes Word Input to the PLC from the Module Scale Units RTD Input to Digital ConversionSignals EffectOut-of-Range Input Effect of Voltage Input 10 Ohm Copper Input Resolution ResolutionInstalling and Configuring the Module Calculating the I/O Base Power BudgetSelecting 2 and 3 Wire or 4 Wire Operation Installing and Configuring the Module Configuring Temperature or SelectingMillivolt Input Selecting Data Selecting DegreesCelsius or FahrenheitConfiguration Jumper Locations Inserting Module IntoBase Copper Wire Table at 25 Degrees Celsius Wiring the Input ConnectorsPress In Wiring Connector Wiring Diagram for 2, 3, or 4 Wire RTD Wiring Diagram for Millivolt Measurements Cable Grounding Example I/O Configuration Chart Advanced Function Programming Advanced Advanced Software FunctionsIntroduction OverviewSetting the Module ConfigurationJumper Logging Controller I/OMemory Input Channel Data Internal Register StructuresInput and Output Register Offsets Input RegistersPeak/Valley Hold Input Words Input Flag BitsAveraging Output Data RegistersFunction Enable Bits Control RegistersInputs Discrete Handshake Inputs Data Identification Bits OutputsData Loading Process Loading Data into the Simatic 505±2557 ModuleSample Low and High Alarm Setpoints Identifying the Data Being Transferred 11 Enabling the Functions Loaded Loading Programs into the I/O Module 13 Startup Relay Ladder Logic Page Timing Constraints When UsingTiming Overhead for Functions Enabled Timing ConsiderationsAdditional Information about Each Function Default ValuesDefault Function Values Default Function Values for Simatic 505±2557Degrees Fahrenheit Alarm SetpointsDegrees Centigrade orDigital Filtering Averaging Peak and ValleyHold Flag Bits Hold ResetPrecedence FunctionTroubleshooting Symptom Probable Cause Corrective Action 10 Troubleshooting Flow Diagram17 I/O Register Quick Reference I/O Register Quick ReferenceOr K Memory Configuration Tables Page Addressing Worksheet 18 Open RTD Status Bits Items Unique to the Simatic 505±2557 ModuleTroubleshooting Table B-1 Specifications SpecificationsSpecifications subject to change without notice Jumper Settings Log Sheet Customer Response Business Reply Mail