Siemens 505-2557 Agency Approvals, European, Community CE, Technical, Assistance

Page 10

Related Manuals Additional manuals that have relevant information include the following:

SIMATIC 545/555/575 System Manual (PPX:505±8201±x).

SIMATIC 545/555/575 Programming Reference User Manual (PPX:505±8204±x).

SIMATIC 505 TISOFT2t User Manual (PPX:TS505±8101±x).

Refer to material in these manuals as necessary for additional information about programming and operating your 545/555/575 system.

Agency Standards Series 505t products have been developed with consideration of the draft standard of the International Electrotechnical Commission Committee proposed standard (IEC±65A/WG6) for programmable controllers (released as IEC 1131±2, Programmable Controllers, Part 2: Equipment Requirements and Tests, First Edition, 1992±09). Contact Siemens Energy

&Automation, Inc., for information about regulatory agency approvals that have been obtained on Series 505 units.

Agency Approvals

Agency approvals are the following:

 

± UL-listed (industrial control equipment)

 

± CUL (Canadian UL)

 

± FM (Class I, Div. 2, Group A, B, C, D Hazardous Locations)

European

Generally, products listed in this manual comply with the essential

Community (CE)

requirements of European Community EMC Directive, number 89/336/EEC,

Approval

and carry the CE label. See the declaration of conformity included with each

 

CPU for a listing of specific products and compliance details.

Technical

For additional technical assistance, call the Siemens Technical Services

Assistance

Group in Johnson City, Tennessee at 1-800-942-5697 or 423-461-2522, or

 

contact them by e-mail at simatic.hotline@sea.siemens.com. For

 

technical assistance outside the United States, call 49-911-895-7000.

viii

Preface

SIMATIC 505±2557 Installation and Operation Guide

Image 10
Contents Simatic Copyright 1998 by Siemens Energy & Automation, Inc Manual Publication History List of Effective Pages Contents Iv Contents List of Figures List of Tables Preface Community CE Agency ApprovalsEuropean ApprovalDescription 100 Ohm, 10 Ohm, 120 Ohm RTDs, or Millivolt InputsOperating Modes Word Input to the PLC from the Module RTD Input to Digital Conversion Scale UnitsEffect SignalsOut-of-Range Input Effect of Voltage Input 10 Ohm Copper Resolution Input ResolutionCalculating the I/O Base Power Budget Installing and Configuring the ModuleSelecting 2 and 3 Wire or 4 Wire Operation Installing and Configuring the Module Configuring Selecting Temperature orMillivolt Input Fahrenheit Selecting DegreesCelsius or Selecting DataConfiguration Jumper Locations Module Into InsertingBase Wiring the Input Connectors Copper Wire Table at 25 Degrees CelsiusPress In Wiring Connector Wiring Diagram for 2, 3, or 4 Wire RTD Wiring Diagram for Millivolt Measurements Cable Grounding Example I/O Configuration Chart Advanced Function Programming Overview Advanced Software FunctionsIntroduction AdvancedConfiguration Setting the ModuleJumper Controller I/O LoggingMemory Input Registers Internal Register StructuresInput and Output Register Offsets Input Channel DataInput Flag Bits Peak/Valley Hold Input WordsOutput Data Registers AveragingControl Registers Function Enable BitsInputs Discrete Handshake Inputs Outputs Data Identification BitsLoading Data into the Simatic 505±2557 Module Data Loading ProcessSample Low and High Alarm Setpoints Identifying the Data Being Transferred 11 Enabling the Functions Loaded Loading Programs into the I/O Module 13 Startup Relay Ladder Logic Page Timing Considerations When UsingTiming Overhead for Functions Enabled Timing ConstraintsDefault Function Values for Simatic 505±2557 Default ValuesDefault Function Values Additional Information about Each FunctionCentigrade or Alarm SetpointsDegrees Degrees FahrenheitDigital Filtering Peak and Valley AveragingHold Hold Reset Flag BitsFunction PrecedenceTroubleshooting 10 Troubleshooting Flow Diagram Symptom Probable Cause Corrective ActionI/O Register Quick Reference 17 I/O Register Quick ReferenceOr K Memory Configuration Tables Page Addressing Worksheet Items Unique to the Simatic 505±2557 Module 18 Open RTD Status BitsTroubleshooting Specifications Table B-1 SpecificationsSpecifications subject to change without notice Jumper Settings Log Sheet Customer Response Business Reply Mail