Siemens 505-2557 installation and operation guide Press In Wiring Connector

Page 26

To assign an input to a specific channel, locate the appropriate channel position on the press in connector block as shown in the following figure (each channel consists of 4 positions).

Figure 2-4 Press In Wiring Connector

NOTE: RTD wires must be of the same gauge for proper lead length compensation.

SIMATIC 505±2557 Installation and Operation Guide

Installation

2-9

Image 26
Contents Simatic Copyright 1998 by Siemens Energy & Automation, Inc Manual Publication History List of Effective Pages Contents Iv Contents List of Figures List of Tables Preface Community CE Agency ApprovalsEuropean ApprovalDescription 100 Ohm, 10 Ohm, 120 Ohm RTDs, or Millivolt InputsOperating Modes Word Input to the PLC from the Module RTD Input to Digital Conversion Scale UnitsOut-of-Range Input SignalsEffect Effect of Voltage Input 10 Ohm Copper Resolution Input ResolutionSelecting 2 and 3 Wire or 4 Wire Operation Installing and Configuring the ModuleCalculating the I/O Base Power Budget Installing and Configuring the Module Configuring Millivolt Input Temperature orSelecting Fahrenheit Selecting DegreesCelsius or Selecting DataConfiguration Jumper Locations Base InsertingModule Into Wiring the Input Connectors Copper Wire Table at 25 Degrees CelsiusPress In Wiring Connector Wiring Diagram for 2, 3, or 4 Wire RTD Wiring Diagram for Millivolt Measurements Cable Grounding Example I/O Configuration Chart Advanced Function Programming Overview Advanced Software FunctionsIntroduction AdvancedJumper Setting the ModuleConfiguration Memory LoggingController I/O Input Registers Internal Register StructuresInput and Output Register Offsets Input Channel DataInput Flag Bits Peak/Valley Hold Input WordsOutput Data Registers AveragingInputs Function Enable BitsControl Registers Discrete Handshake Inputs Outputs Data Identification BitsLoading Data into the Simatic 505±2557 Module Data Loading ProcessSample Low and High Alarm Setpoints Identifying the Data Being Transferred 11 Enabling the Functions Loaded Loading Programs into the I/O Module 13 Startup Relay Ladder Logic Page Timing Considerations When UsingTiming Overhead for Functions Enabled Timing ConstraintsDefault Function Values for Simatic 505±2557 Default ValuesDefault Function Values Additional Information about Each FunctionCentigrade or Alarm SetpointsDegrees Degrees FahrenheitDigital Filtering Hold AveragingPeak and Valley Hold Reset Flag BitsFunction PrecedenceTroubleshooting 10 Troubleshooting Flow Diagram Symptom Probable Cause Corrective ActionI/O Register Quick Reference 17 I/O Register Quick ReferenceOr K Memory Configuration Tables Page Addressing Worksheet Items Unique to the Simatic 505±2557 Module 18 Open RTD Status BitsTroubleshooting Specifications Table B-1 SpecificationsSpecifications subject to change without notice Jumper Settings Log Sheet Customer Response Business Reply Mail