Heatiator C40 owner manual Maintenance Task List, Replacement Maintenance Glass Replacement

Page 23

6. Maintenance Task List

Inspect

 

Maintenance Tasks

 

 

 

Screens

1.

Assess condition of screen and replace as necessary.

 

 

 

 

2.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Glass Doors

1.

Inspect glass panels for cracks. Replace if this condition is present.

 

 

 

 

2.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

3.

Inspect door rope. Confirm glass does not move around in glass frame

 

 

 

 

4.

Clean glass using a non-abrasive cleaner.

 

 

 

Door Rope

1.

Open door, place half of dollar bill inside, and close door.

(Dollar Bill Test)

 

 

2.

Attempt to pull the bill out.

 

 

 

 

 

3.

If the bill gives good resistance or is not removable, the rope is adjusted correctly.

 

 

If the bill comes out too easily, the door rope needs adjustment to create an even thickness all the way around door.

 

 

 

Circulation Compartment

1.

Remove any foreign objects.

 

 

 

 

2.

Verify unobstructed air circulation.

 

 

 

Firebox

1.

Inspect condition of brick. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 mm).

 

 

 

Chimney

1.

Inspect for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remain intact.

 

 

 

 

6.

Inspect for creosote and remove as needed. (See Section 11)

 

 

 

B. Replacement Maintenance

1.Glass Replacement

1.Ensure that the fire is out and the appliance is cool to the touch.

2.Protect a table or counter top with padding or towels.

3.Remove door with broken glass from the appliance by lifting door up and off of the hinges.

4.Lay door face down on a table or counter making sure handle and handle attachment knob hang over the edge of the table top so door lays flat, on a soft surface.

5.Remove screws from the top and bottom glass frames (5 on each door) using a #2 Phillips Head screwdriver. Set frames aside and retain screws.

HINT: Soak screws in penetrating oil for easy removal.

6.Remove the glass and discard.

7.Position the new glass with edges evenly overlapping the opening in the front door.

8.Replace the glass frames. Be careful not to cross thread the screws.

9.Start screws to secure glass frames to door, keeping them loose for adjusting the glass. Then continue to tighten each screw alternately, a few turns at a time, until the glass panel is tightened snugly. DO NOT OVERTIGHTEN SCREWS.

10.Replace the door on the appliance.

11.After the first burn, recheck the tightness of the screws.

NOTICE: Remove all labels from glass before lighting the first fire in your APPLIANCE.

4/12

Heatilator • Constitution EPA Fireplace • 480-1091H

Page 23

Image 23
Contents Hot screen/mesh and glass doors will cause burns C40009 Listing Label Information/LocationTable of Contents Limited Lifetime Warranty Warranty Conditions Manufactured Home Approved Listing and Code ApprovalsAppliance Certification Combustible Materials BTU & Efficiency Specifications Electrical CodesGlass Specifications Non-Combustible MaterialsHot glass will cause burns Operating InstructionsUser GuideYour Fireplace General Information Baffle and Blanket PlacementFirebrick Placement Seasoning Moisture contentWood Fuel Hardwood vs. SoftwoodStoring Wood Outside AirSeasoned Wood Glass Doors Clear Space Near the FireplaceChimney Fire Fire SafetySymptoms of Over-Firing Over-Firing Your Appliance2nd stage Starting a FireBurning Process Kindling or 1st stageSlide Air Control Slide Left to Stop Automatic Combustion Control ACCFinal stage Opacity Manual Timer OverrideBurn Rates Burning GuidelinesDraft Problems TroubleshootingUnderstanding Vent Problems For start-up? Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Creosote Chimney Cleaning Maintenance and Servicing the FireplaceDoor and Door Gasket Care and Cleaning of Plated SurfacesGlass Cleaning Disposal of AshesReplacement Maintenance Glass Replacement Maintenance Task ListFire Brick Configurations Firebrick ReplacementFan Cord Location Baffle Removal and InstallationFan Replacement Removing the fan Fan Replacement Instructions11 Timer Assembly Timer Assembly ReplacementLinkage Arm Slider Control Rod Timer Removal & ReplacementHeatilator Constitution EPA Fireplace 480-1091H Date of Service Performed By Description of Service Service & Maintenance LogTypical Fireplace System Getting Started Installer GuideNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Selecting Fireplace Locations Framing & ClearancesClearances to Combustible Materials ClearancesMinimum Clearances to Combustibles Within Enclosure Area Frame the FireplaceFan Wiring Diagram Electrical Access and Wiring DiagramInstall the Outside Air Kit Installation of FireplaceMm metal flex Fireplace Or rigid pipe Place Protective Metal Hearth Strips Secure the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeInstalling Flex Pipe Install Ceiling FirestopsSecure the Chimney Install Attic Insulation ShieldCut out Hole in Roof Double-check the Chimney AssemblyComplete Installation Install Flashing13 Multiple Chimney Locations Consult local codes for framing details SL-300 Series Ceiling/Roof ThimbleConstruct the Chase Chase InstallationsInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap TCT375 Terra Cotta Cap = 1/k x inches of thickness FinishingNon-Combustible Materials Non-Combustible Facing Material StallationCardboard or Metal Template Hearth ExtensionNon-Combustible Sealant Material Fireplace and Hearth Extension are flush on the floor Position the Hearth ExtensionRaised Hearth Extension Framing Non-Combustible Material Finishing MaterialCombustible Material Mantel 13 Mantel SpecificationsHeat Zone Kit Optional AccessoriesRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Constitution Fireplace DimensionsReference Materials Catalog Description Catalog No Chimney Components15-3/4 DTO134 Constitution Woodburning Fireplace Service PartsPart number list on following #3 Brick Set StockedAt Depot Stocked at Depot Baffle Protection Channel Door Handle AssemblyThis page intentionally left blank Do not Discard this Manual Contact Information
Related manuals
Manual 71 pages 32.62 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.