Heatiator C40 owner manual Using Offsets/ Returns, Example

Page 44

C. Using Offsets/ Returns

Use an offset/return to bypass overhead obstructions.

An offset and return can be used as a single entity or separated by chimney section(s).

Warning! Risk of Fire! Do not use offset/returns greater than 30°. Chimney draft will be restricted and could cause over- heating and fire. Secure offsets vwith screws ( not to exceed 1/2” / 13 mm in length) Secure returns with strapping. Straight chimney sections may be secured with screws. Keep chimney sections from separating or twisting.

Measure the shift needed to aVOID the overhead obstruction. Refer to dimension A in Figure 8.3.

Find the appropriate A dimension listed in Table 8.2. The B dimension coinciding with the A dimension measurement in Table 8.2 represents the required vertical clearance needed to complete the offset/return.

Read across the chart to find the number of chimney sections/model numbers needed between the offset and return.

A

B

1-1/4 in. (32 mm)

OVERLAP

Figure 8.3 Chimney Offset/Return

Example:

Your “A” dimension from Figure 8.3 is 14 1/2 in. (368 mm). Using Table 8.2 the dimension closest to, but not less than 14 1/2 in. (368 mm) is 14 1/2 in. (368 mm) us- ing a 30° offset/return.

You determine from the table that you need 34 1/8 in. (867 mm) (Dimension “B”) between the offset and return.

The chimney component that best fits your application is one SL324.

Table 8.2

 

 

15-degree

 

 

 

 

 

 

 

 

 

 

30-degree

 

 

 

A

 

B

 

 

 

 

 

 

 

A

 

B

Offset

Height

 

 

 

 

 

 

Offset

Height

in.

 

mm

in.

 

mm

SL306

SL312

SL318

SL324

SL336

SL348

in.

 

mm

in.

 

mm

1-5/8

 

41

13-3/8

 

340

-

-

-

-

-

-

3-5/8

 

92

15-1/2

 

394

2-7/8

 

73

17-3/4

 

451

1

-

-

-

-

-

5-1/2

 

140

18-5/8

 

473

4-1/8

 

102

22-3/8

 

568

2

-

-

-

-

-

7-1/4

 

184

21-3/4

 

552

4-1/2

 

114

23-5/8

 

600

-

1

-

-

-

-

8-1/2

 

216

23-3/4

 

603

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-3/4

 

146

28-1/4

 

718

1

1

-

-

-

-

10-1/4

 

260

27

 

686

6

 

152

29-3/8

 

746

-

-

1

-

-

-

11-1/2

 

292

29

 

737

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-1/4

 

184

34

 

864

-

2

-

-

-

-

13-1/4

 

337

32-1/8

 

816

7-3/4

 

197

36-1/8

 

918

-

-

-

1

-

-

14-1/2

 

368

34-1/8

 

867

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-3/4

 

222

39-3/4

 

1010

1

-

-

1

-

-

16-1/4

 

413

37-3/8

 

949

10-3/8

 

264

45-5/8

 

1159

-

-

2

-

-

-

19-1/4

 

489

42-1/2

 

1080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-5/8

 

270

46-3/4

 

1187

-

-

-

-

1

-

20-1/2

 

521

44-5/8

 

1133

11-7/8

 

302

51-3/8

 

1305

1

-

-

-

1

-

22-1/4

 

565

47-3/4

 

1213

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13-1/2

 

243

57-1/4

 

1454

-

-

-

2

-

-

25-1/4

 

641

52-7/8

 

1343

13-3/4

 

349

58-3/8

 

1483

-

-

-

-

-

1

26-1/2

 

673

55

 

1397

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

381

63

 

1600

1

-

-

-

-

1

28-1/4

 

718

58-1/8

 

1476

16-1/2

 

419

68-3/4

 

1746

-

1

-

-

-

1

31-1/4

 

794

63-1/4

 

1607

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

457

74-5/8

 

1895

-

-

1

-

-

1

34-1/4

 

870

68-1/2

 

1740

19-5/8

 

498

80-3/8

 

2042

-

-

-

1

-

1

37-1/4

 

946

73-3/4

 

1873

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-5/8

 

524

84-1/8

 

2137

1

-

-

1

-

1

39-1/8

 

994

76-7/8

 

1953

22-3/4

 

578

91-7/8

 

2334

-

-

-

-

1

1

43-1/4

 

1099

84-1/8

 

2137

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

610

96-1/2

 

2451

1

-

-

-

1

1

45-1/8

 

1146

87-1/4

 

2216

25-7/8

 

657

103-1/2

 

2629

-

-

-

-

-

2

49-1/4

 

1251

94-1/2

 

2400

Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart.

Page 44

Heatilator • Constitution EPA Fireplace • 480-1091H

4/12

Image 44
Contents C40 Hot screen/mesh and glass doors will cause burnsListing Label Information/Location 009Table of Contents Limited Lifetime Warranty Warranty Conditions Manufactured Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Electrical Codes Glass SpecificationsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsUser GuideYour Fireplace General Information Baffle and Blanket PlacementFirebrick Placement Moisture content Wood FuelHardwood vs. Softwood SeasoningStoring Wood Outside AirSeasoned Wood Clear Space Near the Fireplace Glass DoorsFire Safety Symptoms of Over-FiringOver-Firing Your Appliance Chimney FireStarting a Fire Burning ProcessKindling or 1st stage 2nd stageSlide Air Control Slide Left to Stop Automatic Combustion Control ACCFinal stage Manual Timer Override Burn RatesBurning Guidelines OpacityDraft Problems TroubleshootingUnderstanding Vent Problems For start-up? Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Maintenance and Servicing the Fireplace General Maintenance Creosote Chimney CleaningCare and Cleaning of Plated Surfaces Glass CleaningDisposal of Ashes Door and Door GasketMaintenance Task List Replacement Maintenance Glass ReplacementFirebrick Replacement Fire Brick ConfigurationsFan Cord Location Baffle Removal and InstallationFan Replacement Fan Replacement Instructions Removing the fanTimer Assembly Replacement 11 Timer AssemblyTimer Removal & Replacement Linkage Arm Slider Control RodHeatilator Constitution EPA Fireplace 480-1091H Service & Maintenance Log Date of Service Performed By Description of ServiceGetting Started Installer Guide Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Selecting Fireplace LocationsClearances Clearances to Combustible MaterialsFrame the Fireplace Minimum Clearances to Combustibles Within Enclosure AreaElectrical Access and Wiring Diagram Fan Wiring DiagramInstallation of Fireplace Install the Outside Air KitMm metal flex Fireplace Or rigid pipe Secure the Fireplace Place Protective Metal Hearth StripsChimney Assembly Chimney Requirements Chimney Termination RequirementsUsing Offsets/ Returns ExampleInstalling CAK4A and Flex Pipe Assemble the Chimney SectionsInstall Ceiling Firestops Installing Flex PipeInstall Attic Insulation Shield Secure the ChimneyDouble-check the Chimney Assembly Complete InstallationInstall Flashing Cut out Hole in Roof13 Multiple Chimney Locations SL-300 Series Ceiling/Roof Thimble Consult local codes for framing detailsChase Installations Construct the ChaseInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap TCT375 Terra Cotta Cap Finishing Non-Combustible Materials Non-Combustible Facing MaterialStallation = 1/k x inches of thicknessCardboard or Metal Template Hearth ExtensionNon-Combustible Sealant Material Fireplace and Hearth Extension are flush on the floor Position the Hearth ExtensionRaised Hearth Extension Framing Non-Combustible Material Finishing MaterialCombustible Material 13 Mantel Specifications MantelAccessories Heat Zone Kit OptionalRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Constitution Fireplace DimensionsReference Materials Chimney Components Catalog Description Catalog No15-3/4 DTO134 Constitution Woodburning Fireplace Service PartsPart number list on following #3 Brick Set StockedAt Depot Door Handle Assembly Stocked at Depot Baffle Protection ChannelThis page intentionally left blank Contact Information Do not Discard this Manual
Related manuals
Manual 71 pages 32.62 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.