Heatiator C40 Frame the Fireplace, Minimum Clearances to Combustibles Within Enclosure Area

Page 37

1. MINIMUM CLEARANCES TO COMBUSTIBLES

WITHIN ENCLOSURE AREA:

 

Appliance to backwall

1 in. (25 mm)

Appliance to sidewall

1 in. (25 mm)

Duct boots to framing

0 in. (0 mm)

Top standoffs to header

0 in. (0 mm)

Door opening to sidewall

22-7/8 in. (581 mm)

EXPOSED SURFACES

 

Faceplate to sidewall

16 in. (406 mm)

Heat zone air grills to ceiling

12 in. (305 mm)

MANTEL

Combustible and non-combustible mantel minimum height from base of fireplace to underside of mantel

 

60 in. (1524 mm)

Maximum mantel depth

12 in. (305 mm)

2.Reduced Mantel Height / Optional Framing Construction Required:

Non-combustiblemantel material minimum height from base of fireplace to underside of mantel 46 in. (1168mm) when the following enclosure construction materials are used:

Non-combustible framing materials must be used above fireplace to height of 84 in. (2134mm) from base of fireplace for all construction materials, fram- ing members, sheeting, and all finish materials.

3. NON-COMBUSTIBLE MATERIALS

Materials which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, con- crete, slate, glass or plasters, or any combination thereof.

Warning Fire Risk!

Non-combustbile mantels installed at a reduced height may GET EXTREMELY HOT during use of the fireplace.

DO NOT TOUCH or place heat sensitive combustible items on the mantel

5. CHIMNEY SECTIONS

Chimney sections at any level require a 2 in. (51 mm) minimum air space clearance between the framing and chimney section.

C. Frame the Fireplace

NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

The Constitution Fireplace will fit a framed opening height of 43-7/8 in. (1114 mm) tall and width of 42 in. (1067 mm). The finished cavity depth must be no less than 24 in. (610 mm). Framing must extend straight up all the way to the ceiling.

Figure 6.3 shows a typical framing (using 2 x 4 lumber) of the fireplace, assuming combustible materials are used. All required clearances to combustibles around the fireplace must be adhered to. See Figure 6.2 on page 36. Any fram- ing across the top of the fireplace must be above the level of the top standoffs. (No recess above standoffs.)

2 in.

(51mm)

Materials that are reported as passing ASTM E 136, Stan- dard Test Method for Behavior of Materials, in a Vertical Tube Furnace at 750°C, shall be considered non-combus- tible materials.

4. COMBUSTIBLE MATERIALS

Materials made of (or surfaced with) wood, compressed paper, plant fibers, plastics, or other materials that can ig- nite and burn, whether flame proofed or not, or whether plastered or un-plastered shall be considered combustible materials.

Warning Fire Risk!

43-7/8 in.

(1114mm)

24 in.

(610mm)

12 in.

(305mm)

Position combus- tible / non-combus- tible mantel 60 in. (1524mm) from base of the fireplace

42 in.

(1067mm)

Hearth & Home Technologies is not responsible for dis- coloration, cracking or other material failures of finished materials due to heat exposure or smoke.

Choose finishing materials carefully.

Figure 6.3 Framing the Fireplace

4/12

Heatilator • Constitution EPA Fireplace • 480-1091H

Page 37

Image 37
Contents Hot screen/mesh and glass doors will cause burns C40009 Listing Label Information/LocationTable of Contents Limited Lifetime Warranty Warranty Conditions Appliance Certification Listing and Code ApprovalsManufactured Home Approved Glass Specifications BTU & Efficiency Specifications Electrical CodesNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsUser GuideHot glass will cause burns Firebrick Placement Baffle and Blanket PlacementGeneral Information Wood Fuel Moisture contentHardwood vs. Softwood SeasoningSeasoned Wood Outside AirStoring Wood Glass Doors Clear Space Near the FireplaceSymptoms of Over-Firing Fire SafetyOver-Firing Your Appliance Chimney FireBurning Process Starting a FireKindling or 1st stage 2nd stageFinal stage Automatic Combustion Control ACCSlide Air Control Slide Left to Stop Burn Rates Manual Timer OverrideBurning Guidelines OpacityUnderstanding Vent Problems TroubleshootingDraft Problems For start-up? Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Creosote Chimney Cleaning Maintenance and Servicing the FireplaceGlass Cleaning Care and Cleaning of Plated SurfacesDisposal of Ashes Door and Door GasketReplacement Maintenance Glass Replacement Maintenance Task ListFire Brick Configurations Firebrick ReplacementFan Replacement Baffle Removal and InstallationFan Cord Location Removing the fan Fan Replacement Instructions11 Timer Assembly Timer Assembly ReplacementLinkage Arm Slider Control Rod Timer Removal & ReplacementHeatilator Constitution EPA Fireplace 480-1091H Date of Service Performed By Description of Service Service & Maintenance LogTypical Fireplace System Getting Started Installer GuideDraft Design and Installation ConsiderationsNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Selecting Fireplace Locations Framing & ClearancesClearances to Combustible Materials ClearancesMinimum Clearances to Combustibles Within Enclosure Area Frame the FireplaceFan Wiring Diagram Electrical Access and Wiring DiagramInstall the Outside Air Kit Installation of FireplaceMm metal flex Fireplace Or rigid pipe Place Protective Metal Hearth Strips Secure the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeInstalling Flex Pipe Install Ceiling FirestopsSecure the Chimney Install Attic Insulation ShieldComplete Installation Double-check the Chimney AssemblyInstall Flashing Cut out Hole in Roof13 Multiple Chimney Locations Consult local codes for framing details SL-300 Series Ceiling/Roof ThimbleConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyInstall Termination Cap ST375 Square Termination Cap TCT375 Terra Cotta Cap Non-Combustible Materials Non-Combustible Facing Material FinishingStallation = 1/k x inches of thicknessNon-Combustible Sealant Material Hearth ExtensionCardboard or Metal Template Raised Hearth Extension Framing Position the Hearth ExtensionFireplace and Hearth Extension are flush on the floor Combustible Material Finishing MaterialNon-Combustible Material Mantel 13 Mantel SpecificationsHeat Zone Kit Optional AccessoriesRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Reference Materials Fireplace DimensionsConstitution Catalog Description Catalog No Chimney Components15-3/4 DTO134 Part number list on following Service PartsConstitution Woodburning Fireplace At Depot Stocked#3 Brick Set Stocked at Depot Baffle Protection Channel Door Handle AssemblyThis page intentionally left blank Do not Discard this Manual Contact Information
Related manuals
Manual 71 pages 32.62 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.