Heatiator C40 owner manual Chase Installations, Construct the Chase

Page 51

9Chase Installations

A. Construct the Chase

A chase is a vertical boxlike structure built to enclose the fireplace and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a chase.

In cold climates, it is recommended that the chase insulated using batt type insulation between the joists.

Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner. All outer walls need to be insulated.

Building codes require false ceiling and ceiling firestops at each floor of the chase or every 10 ft (3.05 mm) of clear space to control spread of fire.

Walls, ceiling, base plate and cantilever floor at the first level of the chase should be insulated. See Figure 9.1 Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, Hearth

&Home Technologies recommends that the inside surfac- es be sheet rocked and taped (or the use of an equivalent method) for maximum air tightness.

Three examples of chase applications are shown in Figure 9.2

1.Fireplace and chimney enclosed in an exterior chase.

2.Chimney offset through exterior wall and enclosed in chase.

3.Chase constructed on roof.

All outside walls should be insulated.

1

2

3

Figure 9.2 Chase Constructions

Holes and other openings should be caulked with high tem- perature caulk or stuffed with unfaced fiber glass insulation.

 

 

 

Warning! You must install false ceilings and ceiling

 

 

 

firestops at each floor of the chase or every 10 ft (3.05 m)

Round Termination Cap

 

to control spread of fire.

 

 

 

 

 

Storm Collar

 

Warning! Risk of Fire! Do not seal area between fire

Metal Chase Top

 

 

Ceiling

 

stop opening and chimney pipe except where they enter

 

 

the attic or leave the warm air envelope of the home (use

 

Firestop

 

600° F sealant).

 

 

 

 

 

 

 

 

Warning! Risk of Fire! You must maintain a minimum

 

 

 

2 in. (51 mm) air space clearance to insulation and other

 

False Ceiling

 

materials surrounding the chimney system.

 

 

 

 

 

 

Attic

 

• Insulation and other materials must be firmly secured to

 

 

prevent accidental contact with chimney system.

Tabs

Insulation

 

 

• The chase must be properly blocked to prevent blown

Shield

 

 

 

 

Ceiling

Insulation in the

insulation or other combustibles from entering and

 

Firestop

outside walls

making contact with fireplace or chimney.

 

 

of the chase

 

Insulation

Insulation

 

• Failure to prevent contact between insulation or other

False Ceiling

False Ceiling

 

materials and chimney system may cause overheating

 

Chimney

 

and fire.

 

Figure 9.1

Chase Assembly

 

 

 

4/12

 

Heatilator • Constitution EPA Fireplace • 480-1091H

Page 51

Image 51
Contents Hot screen/mesh and glass doors will cause burns C40009 Listing Label Information/LocationTable of Contents Limited Lifetime Warranty Warranty Conditions Listing and Code Approvals Appliance CertificationManufactured Home Approved Combustible Materials BTU & Efficiency Specifications Electrical CodesGlass Specifications Non-Combustible MaterialsOperating InstructionsUser Guide Your FireplaceHot glass will cause burns Baffle and Blanket Placement Firebrick PlacementGeneral Information Seasoning Moisture contentWood Fuel Hardwood vs. SoftwoodOutside Air Seasoned WoodStoring Wood Glass Doors Clear Space Near the FireplaceChimney Fire Fire SafetySymptoms of Over-Firing Over-Firing Your Appliance2nd stage Starting a FireBurning Process Kindling or 1st stageAutomatic Combustion Control ACC Final stageSlide Air Control Slide Left to Stop Opacity Manual Timer OverrideBurn Rates Burning GuidelinesTroubleshooting Understanding Vent ProblemsDraft Problems For start-up? Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Creosote Chimney Cleaning Maintenance and Servicing the FireplaceDoor and Door Gasket Care and Cleaning of Plated SurfacesGlass Cleaning Disposal of AshesReplacement Maintenance Glass Replacement Maintenance Task ListFire Brick Configurations Firebrick ReplacementBaffle Removal and Installation Fan ReplacementFan Cord Location Removing the fan Fan Replacement Instructions11 Timer Assembly Timer Assembly ReplacementLinkage Arm Slider Control Rod Timer Removal & ReplacementHeatilator Constitution EPA Fireplace 480-1091H Date of Service Performed By Description of Service Service & Maintenance LogTypical Fireplace System Getting Started Installer GuideDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Selecting Fireplace Locations Framing & ClearancesClearances to Combustible Materials ClearancesMinimum Clearances to Combustibles Within Enclosure Area Frame the FireplaceFan Wiring Diagram Electrical Access and Wiring DiagramInstall the Outside Air Kit Installation of FireplaceMm metal flex Fireplace Or rigid pipe Place Protective Metal Hearth Strips Secure the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeInstalling Flex Pipe Install Ceiling FirestopsSecure the Chimney Install Attic Insulation ShieldCut out Hole in Roof Double-check the Chimney AssemblyComplete Installation Install Flashing13 Multiple Chimney Locations Consult local codes for framing details SL-300 Series Ceiling/Roof ThimbleConstruct the Chase Chase InstallationsInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST375 Square Termination Cap TCT375 Terra Cotta Cap = 1/k x inches of thickness FinishingNon-Combustible Materials Non-Combustible Facing Material StallationHearth Extension Non-Combustible Sealant MaterialCardboard or Metal Template Position the Hearth Extension Raised Hearth Extension FramingFireplace and Hearth Extension are flush on the floor Finishing Material Combustible MaterialNon-Combustible Material Mantel 13 Mantel SpecificationsHeat Zone Kit Optional AccessoriesRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Fireplace Dimensions Reference MaterialsConstitution Catalog Description Catalog No Chimney Components15-3/4 DTO134 Service Parts Part number list on followingConstitution Woodburning Fireplace Stocked At Depot#3 Brick Set Stocked at Depot Baffle Protection Channel Door Handle AssemblyThis page intentionally left blank Do not Discard this Manual Contact Information
Related manuals
Manual 71 pages 32.62 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.