Vermont Casting DVT38IN DVT44IN Logs, Position the Log Grate Burner. Remove the two

Page 29

Chateau™

DVT44IN Logs

Log Rear Right

Log Front Middle Right

 

Log Grate Burner

Log Burner Overlay

Log Rear Left

Log Front Right

 

Log Front Upper Right

Log Grate Right

Log Front Left

Log Grate Left

Log Front Middle Left

Log Rear Upper Middle

 

 

LG413

Fig. 42 DVT44IN log identification.

1.Position the Log Grate Burner. Remove the two

(2) screws that attach the fettle to the burner. Place the log grate burner between the notch on the front of the burner housing behind the burner tube. (Fig. 43) Hold the log in place and set the fettle back in position. When the fettle is in position, it must hook onto the log. Refasten fettle in place. NOTE: The log should look as if it has fallen off the grate.

2.Position the Log Burner Overlay. The overlay is very fragile and must be handled with extra care. Hold the overlay with the flat surface facing down.

Figure 43

Log

Burner

Overlay

LG401

Log Grate Burner

The notch for the pilot on the overlay should be in the right rear corner. Set the overlay on top of the burner housing toward the back. The overlay must line up with the sides and back of the burner. The overlay rests behind the log grate burner. Make sure the pilot hood lines up with the notch on the overlay. (Fig. 43)

3.Position the Andirons. Set the andirons in place by hooking the tabs on the back of the andiron over the outermost web of the fettle. (Figs. 49 & 50)

4.Place the Volcanic Rock. Place the volcanic rocks over the hearth refractories in front of the burner tube and around the burner assembly as desired.

(Figs. 49 & 50)

5.Place the Small Lava Rock. Place the small lava rock approximately 1¹⁄₂” (38 mm) wide behind the lip mounted to the burner housing. Place ember material lightly di- rectly behind the lava rock and the overlay.

(Figs. 49 & 50)

6.Place the Ember Material. Place the ember material in front and around the burner tube and behind the burner

tube in front of the burner hous- ing. Build up the ember material lightly over the burner tube into the burner housing to cover up the burner tube and the lip mounted to the front of the burner housing. (Figs. 49 & 50) NOTE: Placing platinum ember material is

mandatory for proper carry over of flame into the burner tube.

20011956

29

Image 29
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsCertified To Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Fireplace Dimensions DVT38IN Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2DVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationUse of the Restrictor Plates Horizontal Venting Applications Sidewall ApplicationsStep Sidewall InstallationVertical height requirement Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plate Installation Glass InformationAppliance Kit Model Description Ceramic Refractory InstallationDVT38IN Logs Log, Lava Rock and Ember PlacementPosition the Log Grate Burner. Remove the two DVT44IN LogsPosition the Log Rear Left Position the Log Front Left. Pos- FigurePosition the Log Front Middle Right DVT38IN logset complete Correct pilot flame appearance Flame CharacteristicsTrim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Igniter operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesFuel Conversion Instructions Conversion PrecautionsConversion Procedure Check Manifold Pressure Converting the Gas Control ValvePilot Flame Adjustment Air Shutter SettingsInjector Orifice Size Matrix Valve Minimum Rate ScrewBurner and Burner Compartment MaintenanceCleaning the Control System DVT38IN, DVT44IN Colonial Red Limestone Herringbone DVT38IN DVT44INFuel Conversion Kits Back-up Battery Kit AccessoriesWall Mountable Wireless Remote Transmitter Ceramic Refractory KitsProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings