Vermont Casting DVT38IN American Flame Gas Control System Error Codes, What to Check

Page 38

Chateau™

American Flame Gas Control System Error Codes

Ignition Safety: Protection for Ignition System

Error Code: One beep every one second

Description of Fault: Warn users if the pilot is not successfully ignited in 60 seconds.

How to Clear: Press OFF then ON buttons to re-attempt ignition.

What to Check:

Ensure gas supply is turned on.

Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.

Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.

Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.

Verify that the black ground lead form the module is connected to a proper ground on the fireplace.

Ensure there is no blockage in the pilot line.

Sensor Safety: Protection for Flame Sensor

Error Code: 4 beeps every one second

Description of Fault: Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence is initiated. This fault will also occur if pilot flame sensor is shorted to ground.

How to Clear: Press OFF then ON buttons to re-attempt normal ignition.

What to Check:

Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).

Replace pilot assembly.

Replace module.

Thermal Safety: Overheat Protection

Error Code: 4 beeps every two seconds.

Description of Fault: Warn users that the module’s internal temperature has exceeded 170° F (77° C).

How to Clear: Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.

What to Check:

Is module located in unapproved location, too close to burner?

Move to cooler location.

Communication Safety: (NOTE: This feature is only available when transmitter includes an LCD screen).

Error Code: One beep every four seconds.

Description of Fault: Warn users that the transmitter and receiver are not communicating properly.

What to Check:

Verify batteries in both transmitter and receiver are new.

Ensure transmitter is located within 20 feet (6 m) of receiver.

Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere with transmission.

38

20011956

Image 38
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Please Review the Following Carefully Installation & Operating InstructionsCertified To Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Fireplace Dimensions DVT38IN Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing Gas Inlet and Manifold Pressures Gas Line InstallationGas Specifications High ElevationsControl System Installation Control SystemSpecial Feature for Cold Climates Inside view of wireless wall switchIntroduction Hand-Held Remote Control Transmitter Operating InstructionsKey Settings LCD Liquid Crystal DisplayManual Function Thermostat FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationDVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal TerminationSidewall Applications Use of the Restrictor Plates Horizontal Venting ApplicationsSidewall Installation StepAlways install horizontal venting on a level plane Vertical height requirementFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberRestrictor Plate Installation Glass Frame Assembly RemovalGlass Cleaning Glass InformationCeramic Refractory Installation Appliance Kit Model DescriptionLog, Lava Rock and Ember Placement DVT38IN LogsDVT44IN Logs Position the Log Grate Burner. Remove the twoPosition the Log Front Left. Pos- Figure Position the Log Rear LeftPosition the Log Front Middle Right DVT38IN logset complete Flame Characteristics Correct pilot flame appearanceTrim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Igniter operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckFuel Conversion Instructions Conversion PrecautionsConversion Procedure Converting the Gas Control Valve Check Manifold PressureInjector Orifice Size Matrix Air Shutter SettingsPilot Flame Adjustment Valve Minimum Rate ScrewBurner and Burner Compartment MaintenanceCleaning the Control System DVT38IN, DVT44IN DVT38IN DVT44IN Colonial Red Limestone HerringboneFuel Conversion Kits Wall Mountable Wireless Remote Transmitter AccessoriesBack-up Battery Kit Ceramic Refractory KitsLimited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %