Vermont Casting DVT38IN installation instructions Trim Installation

Page 34

Chateau™

Trim Installation

CAUTION: Allow fireplace to cool if it has been in operation.

Trim components: Top frame assembly, bottom trim assembly, right and left trim assemblies.

NOTE: Place trim pieces with magnets facing window frame.

1. Place bottom trim on the bottom of the window

 

 

frame. NOTE: Final adjustments will be made

 

Nailing Flange

once all trim pieces are in place.

 

 

2. The right and left trim piece have a 45° notch

 

 

on the back corner of the top end. (Fig. 53)

 

 

Place the right trim against the right side of the

 

 

window frame, making sure the bottom is over-

Trim

 

lapping the bottom trim piece. The right side

 

 

 

of the trim should butt up against the right side

 

 

nailing flange of the fireplace.

 

 

3. Place the left trim on the left side of the window

 

 

frame as in Step 2.

 

 

4. Place the top trim piece so the ends overlap

 

 

both the right and left side trim pieces.

 

 

5. Adjust the top trim so the top butts up against

 

 

the top nailing flange and the sides are butted

 

 

up against the side nailing flanges and the top

 

 

trim. Once the top trims are in place, move the

 

 

bottom trim up until it fits securely with the bot-

 

KT602a

tom of the side trims.

 

Fig. 54

Trim frame in place.

 

Left and Right Trim,

 

 

45° Notch on Top End

 

 

KT601

Fig. 53 The right and left trim pieces have a 45° notch on the back corner of the top end when properly installed.

34

20011956

Image 34
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Certified To Installation & Operating InstructionsPlease Review the Following Carefully Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsGas Equipment Venting System not Provided Fireplace Dimensions DVT38IN Clearance to Combustibles Locating Your FireplaceMantels Framing and Finishing HearthFinal Finishing Gas Inlet and Manifold Pressures Gas Line InstallationGas Specifications High ElevationsControl System Installation Control SystemSpecial Feature for Cold Climates Inside view of wireless wall switchIntroduction Hand-Held Remote Control Transmitter Operating InstructionsKey Settings LCD Liquid Crystal DisplayManual Function Thermostat FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationApplication Quick Reference for Fresh Air Restrictor Plate / Flue BaffleDVT38N DVT38P DVT44N DVT44P General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal TerminationSidewall Applications Use of the Restrictor Plates Horizontal Venting ApplicationsSidewall Installation StepAlways install horizontal venting on a level plane Vertical height requirementFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberRestrictor Plate Installation Glass Frame Assembly RemovalGlass Cleaning Glass InformationCeramic Refractory Installation Appliance Kit Model DescriptionLog, Lava Rock and Ember Placement DVT38IN LogsDVT44IN Logs Position the Log Grate Burner. Remove the twoPosition the Log Front Left. Pos- Figure Position the Log Rear LeftPosition the Log Front Middle Right DVT38IN logset complete Flame Characteristics Correct pilot flame appearanceTrim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingIgniter operation Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckConversion Procedure Conversion PrecautionsFuel Conversion Instructions Converting the Gas Control Valve Check Manifold PressureInjector Orifice Size Matrix Air Shutter SettingsPilot Flame Adjustment Valve Minimum Rate ScrewCleaning the Control System MaintenanceBurner and Burner Compartment DVT38IN, DVT44IN DVT38IN DVT44IN Colonial Red Limestone HerringboneFuel Conversion Kits Wall Mountable Wireless Remote Transmitter AccessoriesBack-up Battery Kit Ceramic Refractory KitsLimited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %