Vermont Casting installation instructions DVT38IN DVT44IN, Colonial Red Limestone Herringbone

Page 44

Chateau™

DVT38IN, DVT44IN (continued)

Ref.

Description

 

 

 

DVT38IN

DVT44IN

1.

Log Set (Complete)

 

 

 

20011953

20011954

1a.

Log Grate Right

 

 

 

20011977 (F39)

20011964 (F54)

1b.

Log Front Left

 

 

 

20011965 (F32)

20011965 (F32)

1c.

Log Front Middle Left

 

 

 

20011966 (F33)

20011966 (F33)

1d.

Log Front Upper Right

 

 

 

20011967 (F41)

20011967 (F41)

1e.

Log Front Right

 

 

 

20011968 (F42)

20011968 (F42)

1f.

Log Rear Upper Middle

 

 

 

--

 

20011969 (F43)

1g.

Log Grate Left

 

 

 

20011978 (F40)

20011970 (F44)

1h.

Log Rear Right

 

 

 

20011971 (F34)

20012714 (F45)

1i.

Log Grate Burner

 

 

 

20011972 (F35)

20011972 (F35)

1j.

Log Front Middle Right

 

 

 

20011973 (F36)

20011973 (F36)

1k.

Log Rear Left

 

 

 

20011974 (F37)

20012715 (F46)

1l.

Log Burner Overlay

 

 

 

20011975 (F38)

20011976 (F55)

1m.

Small Lava Rock Package

 

 

 

57897

 

 

57897

1n.

Volcanic Rock

 

 

 

20000376

20000376

1o.

Bag of Glowing Embers

 

 

 

51915

 

 

51915

1p.

Restrictor

 

 

 

20006959

20005817

2.

Andiron Assembly

 

 

 

20011952

20011952

3.

Fettle

 

 

 

20011950

20011951

 

Ceramic Refractory

Colonial Red

Limestone

 

Herringbone

 

DVT38CRR

DVT44CRR

DVT38CRL

DVT44CRL

DVT38CRH

DVT44CRH

4.

Refractory Set Complete

GAFC5Q0

GAFC500

GAPC5Q0

GAPC500

GALC5Q0

GALC500

5.

Spring Latch Assembly

 

 

 

20005788

20005788

6.

Burner Housing Assembly

 

 

 

20009063

20009029

7.

Burner Tube Assembly

 

 

 

20009081

20008984

8.

Manifold Tube Assembly

 

 

 

20013838

20013683

9a.

Front Orifice 1.55 mm (.061”) - Natural

 

 

--

 

20012877

9a.

Front Orifice #54 (.055”) - Natural

 

 

20000130

 

--

9b.

Front Orifice #63 (.037”) - LP

 

 

 

--

 

20006251

9b.

Front Orifice #66 (.033”) - LP

 

 

 

20009182

 

--

10a.

Middle Orifice #38 (.1015”) - Natural

 

 

--

 

20009310

10a.

Middle Orifice #54 (.055”) - Natural

 

 

20000130

 

--

10b.

Middle Orifice #57 (.043”) - LP

 

 

 

--

 

20004587

10b.

Middle Orifice #59 (.041”) - LP

 

 

 

20000664

 

--

11a.

Rear Orifice #21 (.159”) - Natural

 

 

--

 

20014124

11a.

Rear Orifice #30 (.128”) - Natural

 

 

20009175

 

--

11b.

Rear Orifice #45 (.082”) - LP

 

 

 

--

 

20010169

11b.

Rear Orifice #50 (.070”) - LP

 

 

 

30000337

 

--

12.

Minimum Rate Screw - LP

 

 

 

20012364

20012264

13.

American Flame Valve AF-4034-IN Assembly

 

20011893

20011893

14.

DC Motor, Valve

 

 

 

20011898

20011898

15.

Main Module

 

 

 

20011895

20011895

16.

AC Adaptor

 

 

 

20011900

20011900

17.

24” Wire Harness

 

 

 

20012258

20012258

18.

Pilot Assy 3way N/DV Top Convertible - IN

 

 

10002387

10002387

19.

Remote Control

 

 

 

20011904

20011904

20.

Battery Back-up Accessory Kit Optional (not shown)

 

DVTBBK

DVTBBK

44

20011956

Image 44
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Please Review the Following Carefully Installation & Operating InstructionsCertified To Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Fireplace Dimensions DVT38IN Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing Gas Line Installation Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsControl System Installation Control SystemSpecial Feature for Cold Climates Inside view of wireless wall switchHand-Held Remote Control Transmitter Operating Instructions Key SettingsIntroduction LCD Liquid Crystal DisplayManual Function Thermostat FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationDVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication Canadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationSidewall Applications Use of the Restrictor Plates Horizontal Venting ApplicationsSidewall Installation StepAlways install horizontal venting on a level plane Vertical height requirementFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberGlass Frame Assembly Removal Glass CleaningRestrictor Plate Installation Glass InformationCeramic Refractory Installation Appliance Kit Model DescriptionLog, Lava Rock and Ember Placement DVT38IN LogsDVT44IN Logs Position the Log Grate Burner. Remove the twoPosition the Log Front Left. Pos- Figure Position the Log Rear LeftPosition the Log Front Middle Right DVT38IN logset complete Flame Characteristics Correct pilot flame appearanceTrim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Igniter operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckFuel Conversion Instructions Conversion PrecautionsConversion Procedure Converting the Gas Control Valve Check Manifold PressureAir Shutter Settings Pilot Flame AdjustmentInjector Orifice Size Matrix Valve Minimum Rate ScrewBurner and Burner Compartment MaintenanceCleaning the Control System DVT38IN, DVT44IN DVT38IN DVT44IN Colonial Red Limestone HerringboneFuel Conversion Kits Accessories Back-up Battery KitWall Mountable Wireless Remote Transmitter Ceramic Refractory KitsLimited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %