Vermont Casting DVT38IN installation instructions Control System Installation

Page 9

Control System

The gas control system is located on the right hand side of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit. The system wiring diagram is shown in Figure 11. NOTE: If you choose to install either the optional battery back-up mod- ule, (Model DVTBBK), or the optional wireless wall mountable remote control, (Part #20012267), it is easier to install these at the time of fireplace instal- lation. Refer to Items #11 & #20 in the next section.

Control System Installation

1.Locate the fireplace in the desired location.

2.Remove the glass. Refer to Glass Frame Assembly Removal section.

3.If installed, remove the lava rock, volcanic rock, and- irons, embers and logs, making note of each log’s location.

4.If installed, remove the refractory brick panel right side and rear pieces.

5.Using a back-up wrench, disconnect the gas supply fitting near the right rear corner of the firebox. (Fig. 8)

Pressure Test Ports

Gas Supply Fitting

FP1793

Cover Plate

 

Fig. 8 Disconnect gas supply fitting and remove 13 screws securing the cover plate.

6.Remove pilot assembly from burner assembly by removing two (2) screws.

7.Carefully slide the burner assembly to the left out of the way, taking care not to bend or break the pilot tubes or wiring.

8.Remove 13 screws around the perimeter holding large access panel on the right hand side of the firebox.

9.Carefully pull back the panel just enough to gain ac- cess to control box.

10.Connect the gas supply to the valve. (Fig. 9) Be sure to use a back-up wrench when tightening supply fitting.

Chateau™

Gas Supply

Fitting

FP1794

Fig. 9 Connect gas supply to valve.

11.If you chose to install the optional back-up battery pack (No. DVTBBK), you must install a wall box within 15 feet (4.6 m) of the fireplace. Assemble the connectors on one end of the supplied extension wire harness to the mating connectors on the wire harness within the control box. Make sure to connect black coded wire to black and red coded wire to red.

12.The other end of the extension wire harness should be connected to the wiring of the back-up battery holder located within a wall box.

13.Insert the supplied four (4) “AA” batteries into the battery holder. Be sure to note correct polarity for each battery.

14.Mount electrical wall box containing back-up bat- teries at a convenient location with 15 feet (4.6 m) of the fireplace. Cover wall box using a blank wall plate.

15.Connect a 120V AC electrical supply to the junction box duplex outlet. Use a Romex-type strain relief connector when running wires out through the box knockout. Replace the duplex outlet and cover plate.

16.Plug the AC adaptor plug into the duplex outlet.

17.This control must now be programmed to the re- mote control transmitter(s). To program the remote control(s), make sure the 120V AC is connected and powered to the fireplace.

18.Remove the battery door on the back of the hand held remote control and install two (2) supplied “AAA” batteries. Be sure to note correct polarity. Replace battery door.

19.If you choose to install the optional wireless wall mounted remote control (Part No. 20012267), install two (2) button batteries provided with the remote control by removing four (4) screws holding the back

20011956

9

Image 9
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Installation & Operating Instructions Certified ToPlease Review the Following Carefully Requirements for the Commonwealth of Massachusetts Clear of ALL ObstructionsGas Equipment Venting System not Provided Fireplace Dimensions DVT38IN Locating Your Fireplace Clearance to CombustiblesMantels Hearth Framing and FinishingFinal Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionContinuous Pilot Feature CP Childproof FeatureSetting LOCK-OUT CP Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Quick Reference for Fresh Air Restrictor Plate / Flue Baffle ApplicationDVT38N DVT38P DVT44N DVT44P USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationUse of the Restrictor Plates Horizontal Venting Applications Sidewall ApplicationsStep Sidewall InstallationVertical height requirement Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plate Installation Glass InformationAppliance Kit Model Description Ceramic Refractory InstallationDVT38IN Logs Log, Lava Rock and Ember PlacementPosition the Log Grate Burner. Remove the two DVT44IN LogsPosition the Log Rear Left Position the Log Front Left. Pos- FigurePosition the Log Front Middle Right DVT38IN logset complete Correct pilot flame appearance Flame CharacteristicsTrim Installation Lighting & Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Troubleshooting American Flame Gas Control SystemIgniter operation Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesConversion Precautions Conversion ProcedureFuel Conversion Instructions Check Manifold Pressure Converting the Gas Control ValvePilot Flame Adjustment Air Shutter SettingsInjector Orifice Size Matrix Valve Minimum Rate ScrewMaintenance Cleaning the Control SystemBurner and Burner Compartment DVT38IN, DVT44IN Colonial Red Limestone Herringbone DVT38IN DVT44INFuel Conversion Kits Back-up Battery Kit AccessoriesWall Mountable Wireless Remote Transmitter Ceramic Refractory KitsProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings