Vermont Casting DVT38IN Injector Orifice Size Matrix, Air Shutter Settings, Pilot Flame Adjustment

Page 41

Chateau™

 

 

 

Table 1

Injector Orifice Size Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion to LP

 

 

 

 

 

 

 

 

 

Burner Orifice

 

 

Input (BTU/hr)

Kit #

Model

Front

Part #

 

Middle

Part #

Rear

Part #

Minimum

Maximum

20011992

DVT38IP

#66

20009182

 

#59

20000664

#50

30000337

34,000

46,000

 

 

(.033”)

 

 

(.041”)

 

(.070”)

 

 

 

20012367

DVT44IP

#63

20006251

 

#57

20004587

#49

20006252

45,000

60,000

 

 

(.037”)

 

 

(.043”)

 

(.073”)

 

 

 

Table 2 Air Shutter Settings

Conversion to LP

 

Burner Tube

Burner Housing

Model

Air Shutter Setting

Air Shutter Setting

DVT38IP

Fully open

n/a

DVT44IP

Fully open

Fully open

Table 3 Valve Minimum Rate Screw

Model

Size

Part #

DVT38IP

#31 (.120”)

20012364

DVT44IP

No Shank Screw

20012264

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor should be engulfed in the pilot flame. (Page 33, Fig. 55)

To adjust pilot burner:

1.Locate pilot adjustment screw on the valve next to the black plastic cap. Refer to Page 35.

2.Adjust pilot screw to provide proper sized flame. Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust any other screws on the valve.

20011956

41

Image 41
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsCertified To Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsClear of ALL Obstructions Fireplace Dimensions DVT38IN Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsControl System Control System InstallationInside view of wireless wall switch Special Feature for Cold ClimatesKey Settings Hand-Held Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionSetting LOCK-OUT CP Continuous Pilot FeatureCP Childproof Feature Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2DVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationUse of the Restrictor Plates Horizontal Venting Applications Sidewall ApplicationsStep Sidewall InstallationVertical height requirement Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plate Installation Glass InformationAppliance Kit Model Description Ceramic Refractory InstallationDVT38IN Logs Log, Lava Rock and Ember PlacementPosition the Log Grate Burner. Remove the two DVT44IN LogsPosition the Log Rear Left Position the Log Front Left. Pos- FigurePosition the Log Front Middle Right DVT38IN logset complete Correct pilot flame appearance Flame CharacteristicsTrim Installation Turning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Igniter operation TroubleshootingAmerican Flame Gas Control System Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesFuel Conversion Instructions Conversion PrecautionsConversion Procedure Check Manifold Pressure Converting the Gas Control ValvePilot Flame Adjustment Air Shutter SettingsInjector Orifice Size Matrix Valve Minimum Rate ScrewBurner and Burner Compartment MaintenanceCleaning the Control System DVT38IN, DVT44IN Colonial Red Limestone Herringbone DVT38IN DVT44INFuel Conversion Kits Back-up Battery Kit AccessoriesWall Mountable Wireless Remote Transmitter Ceramic Refractory KitsProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings