Meco 6512S0DT91, 6212S00T91 manual Clean the Burners. See How to Clean Burners in Care, Maintenance

Page 34

34

Troubleshooting

Problem

 

Possible Cause

 

Solution

Regulator coupling nut is not fully connected to LP cylinder

LP-Excess flow valve tripped in regulator

Vapor lock in connections

Tighten coupling nut by hand about one-half to three quar- ters additional turn. Do not use tools.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

 

 

Obstructions in Burners

 

Clean the Burners. See “How to Clean Burners” in Care

 

 

 

 

and Maintenance.

 

 

Wet Electrodes and Burners

 

Dry Electrode with clean cloth. Air dry or use blow dryer.

 

 

Wire loose or disconnected

 

Reconnect the wire.

 

 

Wire shorting (sparking

 

Replace Igniter Wire/Electrode assembly.

 

 

between Igniter and Electrode)

 

(Call the Customer Service Department)

 

 

 

 

 

Burners will not light Burners not assembled correctly

 

See re-assembly after cleaning in Care and Maintenance.

using a match

 

 

 

 

LP Gas Cylinder is empty

 

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

 

 

LP-Excess flow valve tripped in

 

Turn Control Knobs to “Off” position and turn LP Gas Cyl-

 

 

regulator

 

inder handle clockwise until it stops. Wait five minutes. Relight

 

 

 

 

LP gas grill. If flame continues to be low, turn off gas at LP Gas

 

 

 

 

Cylinder and grill. Disconnect the regulator from the LP Gas

 

 

 

 

Cylinder. Reconnect the regulator to the LP Gas Cylinder. This

 

 

 

 

will reset the excess flow valve Perform a leak test. Relight grill.

Regulator Coupling nut is not fully connected to LP Gas Cylinder

Obstructions in Burners

Low flame or low heat LP-gas in LP Gas Cylinder is low

Excess flow valve tripped in regulator

Tighten Regulator Coupling nut by hand about one-half to three quarters additional turn. Do not use tools.

See “How to Clean Burners” in Care and Maintenance.

Check LP Gas Cylinder. Refill if necessary.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

Flames blow out

High or gusting winds

Turn front of grill away from wind or increase flame height.

 

Gas in LP cylinder is low

Check LP Gas Cylinder. Refill if necessary.

 

Excess flow valve tripped

See “Low flame” problem above.

Image 34
Contents DA N G E R Tools Required for Assembly Carbon Monoxide HazardContents Preparation for AssemblyParts Illustration Model 6212S00T91 / 6512S0DT91 Key Description Quantity Parts List- Model / 6212S00T91 / 6512S0DT91DescriptionQuantity Assembly Instructions Step Frame IdentificationFront Crossbrace Assembly Step Shroud to Leg AssemblyStep Step Tank Side Brace & Top Crossbrace Assembly Back ViewStep Crossbrace & Right Tube Brace Assembly Step Tank Locking Plate & Center Crossbrace AssemblyModel Wheel Assembly Step Bowl Support & Hinge Half Assembly Step Drip Cup Wire AssemblyStep Main Burner Assembly 6512 only Tank Heat Shield AttachmentStep Bowl to Cart Assembly Step Manifold Assembly Piezo Igniter Assembly on ModelStep Control Panel Assembly Control Panel Heat Shield Model 6512 onlyElectrode Wire Plug Assembly Step Main Burner Electrode AssemblyModel Step Side Table Assembly Step Hood Hinge Half AssemblyStep Hood Handle Assembly Step Hood/Hinge AssemblyStep Flavor Activator / Warming Rack Assembly Step Cooking Grid / Control Knob AssemblyStep Tank Blocking Wire Assembly Step Drip Cup Assembly Step Battery Installation 6512 onlyUsing Gas Connecting/Disconnecting the GasLP Gas Cylinder Disconnecting LP Gas Cylinder Connecting LP Gas CylinderLP Hose and Regulator Selecting a Location Before Using Your LP Gas GrillInstallation Codes Performing a Leak TestHow to Perform a Leak Test First Time USE and as required Lighting the Grill Using the Ignitor Check The FlameManual Lighting of the Grill on Off positionManually Lighting the Grill Cooking On the Gas Grill Grill Cooking Direct MethodDirect Cooking on the Grids Roasting Indirect MethodIndirect Cooking Roasting Warming Rack Care and MaintenanceCleaning the Grill End of Cooking SessionCooking Grid/Flavor Activators All Other CleaningHow to Clean the Burners BurnersStorage See Grill Cart, Bowl and Hood pTroubleshooting EmergenciesMaintenance Clean the Burners. See How to Clean Burners in CareSee How to Clean Burners in Care and Maintenance Problem Important NoticeLimited Warranty Meco Corporation Limited Warranty