Cisco Systems CGS 2520 manual Dual-Purpose Gigabit Ethernet Ports, SFP Modules

Page 13

Chapter 1 Product Overview

Ports

Note The output of the PoE+ circuit has been evaluated as a Limited Power Source (LPS) per IEC 60950-1.

Dual-Purpose Gigabit Ethernet Ports

You can configure the dual-purpose ports on the switch as either 10/100/1000 ports or as SFP module ports. You can set the 10/100/1000 ports to autonegotiate, or you can configure them as fixed 10, 100, or 1000 Mb/s (Gigabit) Ethernet ports.

By default, the switch selects the medium for each dual-purpose port (10/100/1000BASE-T or SFP). When a link is achieved on one media type, the switch disables the other media type until the active link goes down. If links are active on both media, the SFP module port has priority, but you can use the media-typeinterface configuration command to manually designate the port as an RJ-45 port or an SFP port.

You can configure the speed and duplex settings consistent with the selected media type. For information on configuring interfaces, see the CGS 2520 Switch Software Configuration Guide on Cisco.com.

For more information on the SFP module ports see:

SFP Modules, page 1-5

SFP Module Patch Cable, page 1-6

SFP Modules

The switch Ethernet SFP modules provide connections to other devices. These field-replaceable transceiver modules provide the uplink interfaces.The modules have LC connectors for fiber-optic connections or RJ-45 connectors for copper connections. You can use any combination of the supported SFP modules listed in Table 1-2.

Cisco CGS 2520 Hardware Installation Guide

 

OL-31444-01

1-5

 

 

 

Image 13
Contents Cisco CGS 2520 Hardware Installation Guide Page N T E N T S Wall-Mounting Troubleshooting Accessing the CLI Through the Console Port C-1 Preface Related Publications Obtaining Documentation and Submitting a Service RequestProduct Overview Cable Side Switch Models Model Description Cisco CGS-2520-16S-8PC Cable-Side View PortsPoE and PoE+ Ports 10/100BASE-T PortsSFP Modules Dual-Purpose Gigabit Ethernet PortsType of SFP Module Model SFP Module Patch CableAlarm Ports Power-Input TerminalAlarm Input Alarm OutputManagement Ports LEDsSystem LED Switch Panel LEDsColor System Status Alarm LEDs Power Supply Module LEDsConsole LEDs PoE LED Port LEDsColor Description LED Color MeaningSD Flash Memory Card Power Supply SideDual-Purpose Port LEDs SD Flash Memory Card LEDPSU OK LED Power Supply Features Power Supply-Side LEDsManagement Options Network Configurations Switch Installation 140F 60C Statement Verifying Switch Operation Installation Guidelines75 in .4 cm. Statement Mounting into a Rack Installing the SwitchMounting Brackets 2shows the 23-inch rack mounting brackets Attaching Brackets for 19-Inch RacksAttaching Brackets for 19-Inch Racks Attaching Brackets for 19-Inch Racks IP-30 Compliance Inserting the Rubber Plugs Inserting the Rubber Plugs Inserting the Rubber Plugs detail Attaching Brackets for 19-Inch Racks 10 Attaching Brackets for 19-Inch Racks Attaching Brackets for 23-Inch Racks11 Attaching Brackets for 23-Inch Racks Attaching Brackets for Etsi Racks12 Attaching Brackets for Etsi Racks Mounting the Switch into a Rack Attaching Brackets for Wall Mounting Wall-Mounting14 Attaching 19-inch Rack Brackets for Wall Mounting Wall-Mounting for IP-30 Compliance15 Inserting the Rubber Plugs into the Switch Holes Installing SFP Modules Installing and Removing SFP ModulesRemoving SFP Modules 17 Installing an SFP Module18 Removing a Bale Clasp Latch SFP Module Inserting and Removing the SFP Module Patch CableRemoving the SFP Module Patch Cable Replacing the SD Flash Memory Card21 Loosening the Captive Screw Device Crossover Cable Straight-Through Cable Connecting Devices to the Ethernet PortsConnecting to the 10/100 PoE+ Ports Connecting to the 10/100 and 10/100/1000 PortsWhere to Go Next Power Supply Modules Power Supply InstallationPWR-RGD-AC-DC Power Supply Module Power Supply Module InstallationInstalling a Power Supply Module Installation GuidelinesEquipment That You Need Grounding the Switch Dual-hole terminal lug Loosen the Screws on the Power Supply Blank Installing the Power Supply Module in the SwitchAC 5 A, DC 15 a Statement Wiring the Power SourcePSU2 11 Stripping the Input Power Source Wire 12 Crimping the Spade Terminal Lug AC power Removing the Power Supply Module15 Removing the Screws Switch Post Results Diagnosing ProblemsSwitch LEDs Bad or Damaged Cable Switch ConnectionsEthernet and Fiber-Optic Cables Link Status10/100 PoE+ Port Connections 10/100 and 10/100/1000 Port ConnectionsSFP Module Interface Settings Switch PerformancePing End Device Spanning Tree LoopsCabling Distance Auto-Negotiation and Network Interface CardsFinding the Switch Serial Number Resetting the Switch to the Factory Default SettingsPhysical Specifications Switch SpecificationsEnvironmental Ranges Power Requirements Power Requirements Power Specifications Power Supply Module Specifications10/100 Ethernet Ports Connector SpecificationsFigure B-2 Fiber-Optic SFP Module LC Connector SFP Module ConnectorsAlarm Ratings Alarm PortDual-Purpose Ports SFP Module Cables Cables and AdaptersIndustrial and Rugged SFPs Commercial SFPs100BASE-BX Cable Pinouts Extended temperature SFPsFigure B-6 DSR DTR CTS RTS Console Port Adapter PinoutsSwitch Console RJ-45-to-DB-25 Port DTE Adapter Device OL-31444-01 RJ-45 Console Port Accessing the CLI Through the Console PortFigure C-1 Connecting the Console Cable USB Console Port Figure C-2 Connecting the USB Console CableInstalling the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows USB Device DriversInstalling the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows Vista USB Driver Uninstalling the Cisco Microsoft Windows USB DriversIP Settings Entering the Initial Configuration InformationUninstalling the Cisco Microsoft Windows Vista USB Driver Completing the Setup Program These choices appear