Chapter 1 Product Overview
Ports
You can order this cable (part number
Power-Input Terminal
The
Figure 1-4 Power-Input Terminal
Cisco CGS 2520
207234
Alarm Ports
The switch has four alarm inputs and one alarm output. The alarm setting is open or closed.
•Open means that the normal condition has current flowing through the contact (referred to as a normally closed contact). The alarm is generated when the current stops.
•Closed means that no current flows through the contact (referred to as a normally open contact). The alarm is generated when the current flows.
This section contains the following alarm port information:
•Alarm Input, page
•Alarm Output, page
Alarm Input
The alarm input is a
Alarm Output
The alarm output can be configured as a minor or major alarm. Output alarms often control an external alarm, such as a bell or a light. To connect an external alarm device to the relay, connect two relay contact wires to complete the electrical circuit. See the “Alarm Port” section on page
Cisco CGS 2520 Hardware Installation Guide
|
| ||
|
|