Cisco Systems CGS 2520 10/100 and 10/100/1000 Port Connections, 10/100 PoE+ Port Connections

Page 65

Chapter 4 Troubleshooting

Diagnosing Problems

Make sure that both ends of the cable are connected to the correct ports.

Verify that both devices have power.

Verify that you are using the correct cable type. See the “Connector and Cable Specifications” section on page B-1for information.

Look for loose connections. Sometimes a cable appears to be seated but is not. Disconnect the cable, and then reconnect it.

10/100 and 10/100/1000 Port Connections

A port appears to malfunction:

Verify the status of all ports. See Table 1-8 on page 1-11for descriptions of the LEDs and their meanings.

Use the show interfaces privileged EXEC command to see if the port is error-disabled, disabled, or shut down. Re-enable the port if necessary.

Verify the cable type. See the “Connector and Cable Specifications” section on page B-1

10/100 PoE+ Port Connections

A powered device connected to a PoE+ port does not receive power:

Verify the status of all the ports. See Table 1-8for descriptions of the LEDs and their meanings.

Use the show interfaces privileged EXEC command to see if the port is error-disabled, disabled, or shutdown. Re-enable the port if necessary.

Verify the cable type. Many legacy powered devices, including older Cisco IP phones and access points that do not fully support IEEE 802.3af or IEEE 802 (PoE and PoE+ standards) might not support PoE or PoE+ when connected to the switch by a crossover cable. Replace the crossover cable with a straight-through cable.

Caution Noncompliant cabling or powered devices can cause a PoE or PoE+ port fault. Use only compliant cabling to connect Cisco prestandard IP Phones, and wireless access points, IEEE 802.3af or IEEE 802.3at-compliant devices.

SFP Module

Use only Cisco SFP modules. Each Cisco module has an internal serial EEPROM that is encoded with security information. This encoding verifies that the module meets the requirements for the switch.

Inspect the SFP module. Exchange the suspect module with a known good module.

Verify that the module is supported on this platform. (The switch release notes on Cisco.com list the SFP modules that the switch supports.)

Use the show interfaces privileged EXEC command to see if the port or module is error-disabled, disabled, or shutdown. Re-enable the port if needed.

Make sure that all fiber-optic connections are clean and securely connected.

Cisco CGS 2520 Hardware Installation Guide

 

OL-31444-01

4-3

 

 

 

Image 65
Contents Cisco CGS 2520 Hardware Installation Guide Page N T E N T S Wall-Mounting Troubleshooting Accessing the CLI Through the Console Port C-1 Preface Related Publications Obtaining Documentation and Submitting a Service RequestProduct Overview Model Description Switch ModelsCable Side Cisco CGS-2520-16S-8PC Cable-Side View PortsPoE and PoE+ Ports 10/100BASE-T PortsSFP Modules Dual-Purpose Gigabit Ethernet PortsType of SFP Module Model SFP Module Patch CableAlarm Ports Power-Input TerminalAlarm Input Alarm OutputManagement Ports LEDsColor System Status Switch Panel LEDsSystem LED Console LEDs Power Supply Module LEDsAlarm LEDs PoE LED Port LEDsColor Description LED Color MeaningSD Flash Memory Card Power Supply SideDual-Purpose Port LEDs SD Flash Memory Card LEDPSU OK LED Power Supply Features Power Supply-Side LEDsManagement Options Network Configurations Switch Installation 140F 60C Statement 75 in .4 cm. Statement Installation GuidelinesVerifying Switch Operation Mounting Brackets Installing the SwitchMounting into a Rack 2shows the 23-inch rack mounting brackets Attaching Brackets for 19-Inch RacksAttaching Brackets for 19-Inch Racks Attaching Brackets for 19-Inch Racks IP-30 Compliance Inserting the Rubber Plugs Inserting the Rubber Plugs Inserting the Rubber Plugs detail Attaching Brackets for 19-Inch Racks 10 Attaching Brackets for 19-Inch Racks Attaching Brackets for 23-Inch Racks11 Attaching Brackets for 23-Inch Racks Attaching Brackets for Etsi Racks12 Attaching Brackets for Etsi Racks Mounting the Switch into a Rack Attaching Brackets for Wall Mounting Wall-Mounting14 Attaching 19-inch Rack Brackets for Wall Mounting Wall-Mounting for IP-30 Compliance15 Inserting the Rubber Plugs into the Switch Holes Installing SFP Modules Installing and Removing SFP ModulesRemoving SFP Modules 17 Installing an SFP Module18 Removing a Bale Clasp Latch SFP Module Inserting and Removing the SFP Module Patch CableRemoving the SFP Module Patch Cable Replacing the SD Flash Memory Card21 Loosening the Captive Screw Device Crossover Cable Straight-Through Cable Connecting Devices to the Ethernet PortsConnecting to the 10/100 PoE+ Ports Connecting to the 10/100 and 10/100/1000 PortsWhere to Go Next Power Supply Modules Power Supply InstallationPWR-RGD-AC-DC Power Supply Module Power Supply Module InstallationEquipment That You Need Installation GuidelinesInstalling a Power Supply Module Grounding the Switch Dual-hole terminal lug Loosen the Screws on the Power Supply Blank Installing the Power Supply Module in the SwitchAC 5 A, DC 15 a Statement Wiring the Power SourcePSU2 11 Stripping the Input Power Source Wire 12 Crimping the Spade Terminal Lug AC power Removing the Power Supply Module15 Removing the Screws Switch LEDs Diagnosing ProblemsSwitch Post Results Bad or Damaged Cable Switch ConnectionsEthernet and Fiber-Optic Cables Link StatusSFP Module 10/100 and 10/100/1000 Port Connections10/100 PoE+ Port Connections Interface Settings Switch PerformancePing End Device Spanning Tree LoopsCabling Distance Auto-Negotiation and Network Interface CardsFinding the Switch Serial Number Resetting the Switch to the Factory Default SettingsEnvironmental Ranges Switch SpecificationsPhysical Specifications Power Requirements Power Requirements Power Specifications Power Supply Module Specifications10/100 Ethernet Ports Connector SpecificationsFigure B-2 Fiber-Optic SFP Module LC Connector SFP Module ConnectorsDual-Purpose Ports Alarm PortAlarm Ratings SFP Module Cables Cables and AdaptersIndustrial and Rugged SFPs Commercial SFPs100BASE-BX Cable Pinouts Extended temperature SFPsFigure B-6 DSR DTR CTS RTS Console Port Adapter PinoutsSwitch Console RJ-45-to-DB-25 Port DTE Adapter Device OL-31444-01 RJ-45 Console Port Accessing the CLI Through the Console PortFigure C-1 Connecting the Console Cable USB Console Port Figure C-2 Connecting the USB Console CableInstalling the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows USB Device DriversInstalling the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows Vista USB Driver Uninstalling the Cisco Microsoft Windows USB DriversUninstalling the Cisco Microsoft Windows Vista USB Driver Entering the Initial Configuration InformationIP Settings Completing the Setup Program These choices appear