GE Monogram Professional Outdoor Grills and Cooktop installation instructions LP gas connections

Page 16

Installation

LP TANK TIE-DOWN (for built-in island installations)

Outdoor cooking applicances require an integral means of limiting the movement of the LP gas cylinder. For built-in appliances which require the use of a remote LP gas supply cylinder (island applications), a retaining device must be created.

Lateral movement shall not exceed 1" (25.4 mm) at the retention means. The cylinder, or any portion of, shall not become dislodged from the retention device when a lateral force of equal weight to the cylinder is applied, from any direction, at the center of the vertical height of the cylinder.

Retaining device must not interfere with the operation of the cylinder valve, and no movement shall transmit strain to rigid tubing or pipe/hose connections. Hose must not touch any portion of the grill/appliance. (ANSI Z21 58z 2006/CGA 1.6z 2006)

LP tank is inserted into frame. LP tank is secured with fixed thumbscrew on three sides.

8-1/4"8-1/4"

1" Min.

Tee Nut 1/4-20

Recommended

(3 Sides of Frame)

Thumbscrew 1/4-20 right angle or spaded 2" long (3 required)

TANK DRAWER WITH LP TANK RETAINER LOOP (free-standing models only)

To install the LP tank, fully extend the tank drawer and the lift retainer loop. Place the tank on the drawer bottom, inserting the loop on the bottom of the tank through the hole in the drawer bottom. Tilt the tank forward to lower the retainer loop to engage the top ring on the tank. Insert the coupler sleeve on the regulator over the tank inlet; turn clockwise to tighten. Do not overtighten the coupler. Open the tank valve when ready to use the grill. Always close the tank valve when cooking is complete.

LP GAS GRILL CONNECTIONS TO A GRILL OR COOKTOP

LP Gas Cooktop and Grill Combination Connections

Use this method to connect a single tank to both appliances.

LP gas connections

• Completely close the main valve on the LP tank

supplying the grill.

• Attach one hose to the cooktop gas inlet; tighten.

• Attach one hose to the grill gas inlet; tighten.

• Attach the hose ends from the grill and cooktop to

To Manifold

of Grill

3/8" Flare Tee

From Regulated

LP Tank

To Cooktop

Note: The supplied hoses are different lengths. Connect them to suit your installation situation.

the ends of the supplied 3/8” flare tee as shown.

• Attach the supplied regulator hose assembly to

the 3/8” flare tee as shown.

16

Image 16
Contents Instructions d’installation Instrucciones de instalaciónBefore YOU Begin For Outdoor USE only Contents Design InformationBuilt-In Product Dimensions and ClearancesSide View, All Built-In Grill Models Cart with Side Burners Cart15-1/2 both sides 27 41-7/8 Accessories Accessory Product DimensionsAdvance Planning Choosing the LocationPower cord of this appliance is equipped with a Electrical Supply RequirementsGAS Supply Requirements GAS Type Connections ConversionsOutdoor GRILL, Cooktop and Accessory Cutout Dimensions Grill Cutout Gas and Electrical LocationsTools Required Parts ProvidedMaterials Required not provided ZGU122 Cooktop PartsRemove Packaging from Cart Models Remove Packaging from Cart Models Blade of the appliance dollyRemove Packaging from BUILT-IN Models Cut the banding. Use a box cutter or utility knifeLP Tank TIE-DOWN for built-in island installations LP GAS Grill Connections to a Grill or CooktopLP Gas Cooktop and Grill Combination Connections LP gas connectionsLP GAS Grill Connections to a Grill or Cooktop Natural GAS Grill ConnectionsSingle Gas Cooktop or Grill Connection To connect 20-lb. LP tankTest for Leaks To stop a gas leakInstall Cooktop Bracket with Battery Compartment Install Bracket with Transformer Built-In Models OnlySecurity Loop Installation Instructions ZX18DS Storage Drawer ZX18TC Trash BIN