Installation
WARNING:
TEST FOR LEAKS
A complete gas tightness check must be performed at the installation site.
CAUTION:
To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while performing a leak test . Perform leak test outdoors only. Never perform a leak test with fire or flame. DO NOT SMOKE WHILE PERFORMING THE LEAK TEST.
•Use an approved
•Check to be sure all controls are in the OFF position.
•Turn on the fuel supply. For natural gas, turn manual
•Apply liquid leak detector generously on all connections and fittings. See illustrations.
•If growing bubbles appear on any connection point, IMMEDIATELY turn off the gas supply.
To stop a gas leak:
•Turn off the fuel supply.
•Turn on control knobs to release pressure. Turn controls OFF.
•Wash off soapy solution and towel dry.
•Tighten the loose joint and perform a new leak test .
Natural Gas Leak
Test Points
LP Gas Leak
Test Points
LP Gas Leak Test Points
With Cooktop
To Manifold
of Grill
3/8" | To Cooktop |
Flare Tee |
|
From Regulated
LP Tank