Installation Instructions

LP GAS GRILL CONNECTIONS TO A GRILL OR COOKTOP (cont.)

Single Gas Cooktop or Grill Connection

LP Hose and

Regulator

3/8” Flare

Fitting

20-lb. Type 1 LP Tank

Built-in models shown.

For models installed on carts, open the tank storage drawer on the right side to make the tank connection.

Outdoor Cooktop: Install the cooktop with a separate tank using the same method. Order WB21X10156 Regulator hose assembly for the 20-lb. tank connection.

To connect 20-lb. LP tank:

Attach the regular hose assembly to the brass elbow. Do not use threading compound.

Insert the coupler sleeve on the regulator over the tank inlet; turn clockwise to tighten. Do not overtighten the coupler.

To disconnect from the 20-lb. LP tank:

Turn tank valve to OFF.

Grasp the coupler sleeve, turn counterclockwise and remove.

NATURAL GAS GRILL CONNECTIONS

The gas supply line must be sized to accommodate the outdoor grill and, if present, an outdoor cooktop connected to the same gas supply.

The grill or cooktop and its individual shut-off valve must be disconnected from the gas supply during any pressure testing of the system at test pressures in excess of 1/2 PSIG.

1/2" Male to 3/4"

Female Elbow

The installation of the outdoor grills or cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, latest edition.

Operating pressure is 4" water column. Supply pressure should be 5" to 14" water column. If pressure is more than 14" water column, a step-down regulator is required.

Check with the local gas utility or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the line. If the gas line is too small, the grill will not function properly.

• Install a manual gas shut-off valve in an easily

accessible location.

• Use threading compound on male threads only.

Do not use threading compound on the male end

3/4" NPT to

Regulator 3/4" Flare Fitting

3/4" Min. Dia.

Incoming Natural Gas Supply Pipe

of a flare adapter.

• Make connections as shown.

• Check to be sure the regulator arrow points in the

direction of gas flow, towards the grill and away

from the gas supply.

Flexible ConnectorManual Shut-OffValve

Built-in models shown.

Make connection for models installed on carts in the same manner. The entry for the gas line is on the back of the cart.

Outdoor Cooktop: Install the cooktop using the same method illustrated above for the outdoor grills.

17

Image 17
Contents Instrucciones de instalación Instructions d’installationBefore YOU Begin For Outdoor USE only Design Information ContentsSide View, All Built-In Grill Models Product Dimensions and ClearancesBuilt-In Cart Cart with Side Burners15-1/2 both sides 27 41-7/8 Accessory Product Dimensions AccessoriesChoosing the Location Advance PlanningElectrical Supply Requirements Power cord of this appliance is equipped with aGAS Supply Requirements GAS Type Connections ConversionsGrill Cutout Gas and Electrical Locations Outdoor GRILL, Cooktop and Accessory Cutout DimensionsParts Provided Tools RequiredMaterials Required not provided ZGU122 Cooktop PartsRemove Packaging from Cart Models Blade of the appliance dolly Remove Packaging from Cart ModelsCut the banding. Use a box cutter or utility knife Remove Packaging from BUILT-IN ModelsLP GAS Grill Connections to a Grill or Cooktop LP Tank TIE-DOWN for built-in island installationsLP Gas Cooktop and Grill Combination Connections LP gas connectionsNatural GAS Grill Connections LP GAS Grill Connections to a Grill or CooktopSingle Gas Cooktop or Grill Connection To connect 20-lb. LP tankTo stop a gas leak Test for LeaksSecurity Loop Install Bracket with Transformer Built-In Models OnlyInstall Cooktop Bracket with Battery Compartment Installation Instructions ZX18DS Storage Drawer ZX18TC Trash BIN