VENT-FREE COMPACT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

Shown with Optional

Cabinet Mantel/Hearth

Base Accessory

HDCFTP, HDCFTN, CGCFTP AND CGCFTN

14,000 to 26,000 Btu/Hr with Thermostat

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

Save this manual for future reference.

For more information, visit www.desatech.com

Image 1
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety Information Product Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Assembling Hood Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs If you have not assembled firebox, follow instructions onOptional Mantel Installation Mantel Clearances for BUILT- in InstallationRemoving Upper Louver Assembly Installing Blower AccessoryRemoving Valve Cover Shield Removing Valve Cover ShieldFor Built-In Installation Installing Switch Plate to Valve Cover ShieldAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Read Before Lighting For Your SafetyEquipment Shutoff Valve Propane/LPLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance Shutting Off FireplaceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Burner Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingDelayed ignition of burner Manifold pressure is too low Out when control knob is reODS/pilot lights but flame goes Press in control knob fullyWalls or furniture Cleaners, etc. may turn into Burner orifice Clean burner see CleaningGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Replacement Parts SpecificationsService Hints Technical ServiceModels Cgcftp and Cgcftn Illustrated Parts BreakdownPart Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTY Parts ListAccessories FBD Parts CentralsKeep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Fireplace