Desa HDCFTP installation manual Illustrated Parts Breakdown, Models Cgcftp and Cgcftn

Page 28

ILLUSTRATED PARTS BREAKDOWN

MODELS CGCFTP AND CGCFTN

45

42

9

7

4

10

4

817

7

31

30

8

33

8

3

2

20

35

4

11

13

14 29 24

2512-1

23

8

14

32

34

39

37

19

41

12

5

6

 

38

 

 

43

 

25

 

 

 

28

24

 

26 18

 

15

39

36

 

22

 

 

 

44 27

 

 

 

 

21

 

16

 

 

40

31

28

www.desatech.com

111044-01E

Image 28
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety Information Product Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Providing Adequate Ventilation Assembling HoodAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace BUILT-IN Fireplace Installation Rough Opening for Installing WallIf you have not assembled firebox, follow instructions on Attaching Fireplace to Wall StudsMantel Clearances for BUILT- in Installation Optional Mantel InstallationInstalling Blower Accessory Removing Upper Louver AssemblyRemoving Valve Cover Shield Removing Valve Cover ShieldInstalling Switch Plate to Valve Cover Shield For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before LightingEquipment Shutoff Valve Propane/LPOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off FireplaceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Burner Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyOut when control knob is re Delayed ignition of burner Manifold pressure is too lowODS/pilot lights but flame goes Press in control knob fullyBurner orifice Clean burner see Cleaning Walls or furniture Cleaners, etc. may turn intoGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Models Cgcftp and CgcftnParts List Part Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTYAccessories Parts Centrals FBDKeep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Fireplace