Desa HDCFTP installation manual Warranty Information, Keep this Warranty

Page 32

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

VENT-FREE COMPACT FIREPLACE

DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD- ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO

(2)YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTSʼ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:

2701 Industrial Drive P.O. Box 90004

Bowling Green, KY 42102-9004 www.desatech.com

 

111044-01

 

Rev. E

111044 01

06/04

NOT A UPC

 

Image 32
Contents 14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabinet Mantel/Hearth Base AccessoryHDCFTP, HDCFTN, Cgcftp and Cgcftn Table of Contents Safety Information Provide adequate clearances around air openings Local CodesProduct Information Unpacking Product FeaturesAssembly Providing Adequate Ventilation Assembling HoodAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsLocating Fireplace Installation ItemsCheck GAS Type BUILT-IN Fireplace Installation Rough Opening for Installing WallIf you have not assembled firebox, follow instructions on Attaching Fireplace to Wall StudsMantel Clearances for BUILT- in Installation Optional Mantel InstallationInstalling Blower Accessory Removing Upper Louver AssemblyRemoving Valve Cover Shield Removing Valve Cover ShieldInstalling Switch Plate to Valve Cover Shield For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa For Your Safety Read Before LightingEquipment Shutoff Valve Propane/LPOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off FireplaceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Burner Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyOut when control knob is re Delayed ignition of burner Manifold pressure is too lowODS/pilot lights but flame goes Press in control knob fullyBurner orifice Clean burner see Cleaning Walls or furniture Cleaners, etc. may turn intoGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Models Cgcftp and CgcftnParts List Part Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTYAccessories Parts Centrals FBDLimited Warranty VENT-FREE Compact Fireplace Warranty InformationKeep this Warranty