Desa HDCFTP installation manual Table of Contents

Page 2

WARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 6 of this manual.

This appliance may be installed in an aftermarket,* per- manently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indi- cated on the rating plate. This appliance is not convert- ible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

TABLE OF CONTENTS

Safety Information

3

Cleaning and Maintenance

................................

22

Local Codes

4

Troubleshooting

23

Product Information

4

Specifications

27

Product Features

5

Replacement Parts

27

Unpacking

5

Service Hints

27

Assembly

5

Technical Service

27

Air For Combustion and Ventilation

6

Illustrated Parts Breakdown and Parts List

28

Installation

8

Accessories

30

Operating Fireplace

19

Parts Centrals

31

Inspecting Burner

21

Warranty Information

Back Page

2

www.desatech.com

111044-01E

Image 2
Contents 14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabinet Mantel/Hearth Base AccessoryHDCFTP, HDCFTN, Cgcftp and Cgcftn Table of Contents Safety Information Provide adequate clearances around air openings Local CodesProduct Information Unpacking Product FeaturesAssembly Providing Adequate Ventilation Assembling HoodConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsLocating Fireplace Installation ItemsCheck GAS Type BUILT-IN Fireplace Installation Rough Opening for Installing WallIf you have not assembled firebox, follow instructions on Attaching Fireplace to Wall StudsMantel Clearances for BUILT- in Installation Optional Mantel InstallationInstalling Blower Accessory Removing Upper Louver AssemblyRemoving Valve Cover Shield Removing Valve Cover ShieldInstalling Switch Plate to Valve Cover Shield For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Equipment Shutoff Valve For Your SafetyRead Before Lighting Propane/LPTo Turn OFF GAS To Appliance Operating FireplaceLighting Instructions Shutting Off FireplaceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Burner Flame PatternCabinet Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights but flame goes Out when control knob is reDelayed ignition of burner Manifold pressure is too low Press in control knob fullyGas regulator defective Nance, Replace gas regulator Burner orifice Clean burner see CleaningWalls or furniture Cleaners, etc. may turn into Air in gas line Minute Operate burner until air isGas leak. See Warning Service Hints SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models Cgcftp and CgcftnParts List Part Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTYAccessories Parts Centrals FBDLimited Warranty VENT-FREE Compact Fireplace Warranty InformationKeep this Warranty