Desa HDCFTP installation manual Installing Blower Accessory, Removing Upper Louver Assembly

Page 13

INSTALLATION

Continued

13.Place mantel around fireplace. Be careful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 13, page 12).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 13, page 12).

16.Reinstall top louvers.

1 3/4" Screw

Wood Base

Figure 14 - Attaching Wood Base to

Floor

ASSEMBLING BRASS TRIM (Brass trim shipped with mantel)

1.Remove packaging from three remaining pieces of brass trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 15.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 15).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 15).

6.While firmly holding edges of brass trim to- gether, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set brass assembly aside for later installation.

 

 

Top Brass

 

 

Trim

 

 

Set Screws

Slot

 

Adjusting

 

 

Plate

 

 

 

 

 

Side

 

 

Mitered

Brass

 

 

Edge

Trim

 

Shim

 

 

 

Slot

 

 

 

Figure 15 - Assembling Brass Trim

INSTALLING BLOWER ACCESSORY

GA3450T

 

 

Removing Upper Louver Assembly

To install the blower accessory, you must first

remove the upper louver assembly.

 

1.

Lift screen off heater.

 

2.

Remove 4 screws from louver assembly (see

 

Figure 16). Save these screws.

 

3.

Pull louver assembly straight out from the

 

cabinet. Be careful not to scratch the paint.

 

Set louver assembly and screws aside.

 

 

Blower Bracket

 

 

Mounting Holes

 

 

Upper

 

Screws

Louver

 

Assembly

 

 

Figure 16

- Removing Upper Louver

Assembly

 

 

111044-01E

www.desatech.com

13

Image 13
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety Information Product Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Assembling Hood Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs If you have not assembled firebox, follow instructions onOptional Mantel Installation Mantel Clearances for BUILT- in InstallationRemoving Upper Louver Assembly Installing Blower AccessoryRemoving Valve Cover Shield Removing Valve Cover ShieldFor Built-In Installation Installing Switch Plate to Valve Cover ShieldAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Read Before Lighting For Your SafetyEquipment Shutoff Valve Propane/LPLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance Shutting Off FireplaceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Burner Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingDelayed ignition of burner Manifold pressure is too low Out when control knob is reODS/pilot lights but flame goes Press in control knob fullyWalls or furniture Cleaners, etc. may turn into Burner orifice Clean burner see CleaningGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Replacement Parts SpecificationsService Hints Technical ServiceModels Cgcftp and Cgcftn Illustrated Parts BreakdownPart Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTY Parts ListAccessories FBD Parts CentralsKeep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Fireplace