Desa HDCFTP Attaching Wood Base to Solid Floor, Connecting to GAS Supply, Extension Cord

Page 16

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have

athree-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An un- dersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

ATTACHING WOOD BASE TO SOLID FLOOR

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or ma- sonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 22.

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fastened to floor.

Figure 22 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 45° male flare fitting 5/8"-18 UNF (Unified National FineThread)inletconnectionand the flexible gas line provided.

WARNING:Aqualifiedservice person must connect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 23. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Propane/LP

 

Supply Tank

External

 

Regulator

Vent Pointing Down

Figure 23 - External Regulator with Vent

Pointing Down

16

www.desatech.com

111044-01E

Image 16
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety Information Product Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Providing Adequate Ventilation Assembling HoodAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace BUILT-IN Fireplace Installation Rough Opening for Installing WallIf you have not assembled firebox, follow instructions on Attaching Fireplace to Wall StudsMantel Clearances for BUILT- in Installation Optional Mantel InstallationInstalling Blower Accessory Removing Upper Louver AssemblyRemoving Valve Cover Shield Removing Valve Cover ShieldInstalling Switch Plate to Valve Cover Shield For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before LightingEquipment Shutoff Valve Propane/LPOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off FireplaceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Burner Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyOut when control knob is re Delayed ignition of burner Manifold pressure is too lowODS/pilot lights but flame goes Press in control knob fullyBurner orifice Clean burner see Cleaning Walls or furniture Cleaners, etc. may turn intoGas regulator defective Nance, Replace gas regulator Air in gas line Minute Operate burner until air isGas leak. See Warning Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Models Cgcftp and CgcftnParts List Part Number KEY Hdcftp Hdcftn Cgcftp Cgcftn Description QTYAccessories Parts Centrals FBDKeep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Fireplace