INSTALLATION
Continued
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projec- tions off of the facing material.
Firebox
Mantel Shelf
10"
8"
6"
2 1/2"
Noncombustible |
|
| |
Material May |
|
| |
Project Off this |
|
| |
Surface above |
|
| |
the Firebox | 13" | 16" | |
Hood | |||
|
|
19"
21"
| Note: All vertical |
Supplied | measurements are |
from top of fireplace | |
Firebox | hood opening to |
Hood | bottom of mantel |
Must Be | shelf. These minimum |
Used at | clearances replace any |
All Times | other recommended |
| clearances supplied |
| with your ANSI Z21.11.2 |
| approved gas logs. |
Figure 18 - Minimum Mantel Clearances for Built-In Installation
INSTALLING GAS PIPING TO FIREPLACE LOCATION
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING:Aqualifiedservice person must connect fireplace to gas supply. Follow all local codes.
CAUTION:Neverconnectpro- pane/LP fireplace directly to the propane/LPsupply.Thisfireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.
WARNING: Never connect natural gas fireplace to private
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
•external regulator for propane/LP unit only (supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap (optional)
•tee joint
•pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes) (not provided)