Desa LMFP33PR(A) installation manual Gas leak. See Warning, Statement above

Page 28

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted 1.

Heater burning vapors from

odors

paint, hair spray, glues, clean-

 

ers, chemicals, new carpet,

 

etc. (See IMPORTANT state-

 

ment above)

2.

Low fuel supply (propane/LP

 

only)

3.

Gas leak. See Warning

 

statement above

1.Open window to ventilate room. Stop using odor caus- ing products while heater is running

2.Refill supply tank (propane/ LP only)

3.Locate and correct all leaks (see Checking Gas Connec- tions, page 16)

Fireplace shuts off in use (ODS 1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

able

 

ventilation

2.

Low line pressure

2.

Contact local natural or pro-

3.

ODS/pilot is partially

 

pane/LP gas company

3.

Clean ODS/pilot (see Cleaning

 

clogged

 

and Maintenance, page 24)

Gas odor even when control knob 1.

Gas leak. See Warning

is in OFF position

statement above

2.

Control valve or gas control

 

defective

1.Locate and correct all leaks (see Checking Gas Connec- tions, page 16)

2.Replace control valve or gas control

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement above

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 16)

Dark residue on logs inside

1.

Improper log placement

1.

Properly locate logs (see

of their fireplace Note: After

2.

Drafts or other air currents

 

Installing Logs, page 17)

removing all causes of residue

2.

Eliminate source of drafts

deposits, completely clean fire-

 

affecting flame pattern

 

around heater

place and appliance off residue

3.

Air holes at burner inlet

3.

Clean out air holes at burner inlet.

before reusing appliance

 

blocked

 

Periodically repeat as needed

 

4.

Burner flame holes blocked

4.

Remove blockage

28

www.desatech.com

111604-01L

Image 28
Contents What to do if YOU Smell GAS Table of Contents Safety Information Log Base Assembly Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationElectrical Hookup Installing Hood ExampleConventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelMantel Clearances for Built-In Installation Installing Shield to SupportInstalling GAS Piping to Fireplace Location Installation Items NeededNatural Gas Propane/LPConnecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing LogsModels LMFP33PR and LMFP33NR Models LMFP33PRA and LMFP33NRA MiddleInstalling Batteries in Receiver Installing Battery into RemoteOperating Heater For Your Safety Read Before LightingLighting Instructions Procedure To Turn OFF GASTo Appliance Manual LightingHAND-HELD Remote Operation Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerPilot AIR Inlet Hole Burner Injector HolderLogs Troubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Gas leak. See Warning Statement aboveSpecifications Wiring Diagram Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Models LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA ShownParts List Firebox LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA KEY Part Number Description QTY Accessories Blower Accessory GA3750A and GA3650TB SeriesEquipment Shutoff Valve GA5010 Information Video111604-01L Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace