Desa LMFP33PR(A) Checking GAS Connections, Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa

Page 16

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and fireplace. See guidelines under Connecting Fireplace to Gas

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 23).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figures 24 or 25). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment Open

Shutoff

Valve

Closed

Figure 23 - Equipment Shutoff Valve

Supply, page 15.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect fireplace with its appliance main

gas valve (control valve) and equipment

shutoff valve from gas supply piping system.

Pressures in excess of 1/2 psig will damage

fireplace regulator.

Gas Control Valve

Equipment

Shutoff

Valve

Gas Meter

2.

Cap off open end of gas pipe where equipment

 

shutoff valve was connected.

3.

Pressurize supply piping system by either

 

opening propane/LP supply tank valve for

 

propane/LP gas or opening main gas valve

 

located on or near gas meter for natural gas

 

or using compressed air.

4.

Check all joints of gas supply piping system.

 

Apply noncorrosive leak detection fluid to all

 

joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Reconnect fireplace and equipment shutoff

 

valve to gas supply. Check reconnected fit-

 

tings for leaks.

Figure 24 - Checking Gas Joints for

Natural Gas

Equipment Shutoff Valve

Propane/LP

Supply Tank

Gas Control Valve

Figure 25 - Checking Gas Joints for

Propane/LP Gas

16

www.desatech.com

111604-01L

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety Information Log Base Assembly Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationElectrical Hookup Installing Hood ExampleConventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelMantel Clearances for Built-In Installation Installing Shield to Support Installing GAS Piping to Fireplace Location Installation Items NeededNatural Gas Propane/LPConnecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing LogsModels LMFP33PR and LMFP33NR Models LMFP33PRA and LMFP33NRA MiddleInstalling Batteries in Receiver Installing Battery into RemoteOperating Heater For Your Safety Read Before LightingLighting Instructions Procedure To Turn OFF GASTo Appliance Manual LightingHAND-HELD Remote Operation Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerPilot AIR Inlet Hole Burner Injector HolderLogs Troubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Gas leak. See Warning Statement aboveSpecifications Wiring Diagram Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Models LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA ShownParts List Firebox LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA KEY Part Number Description QTY Accessories Blower Accessory GA3750A and GA3650TB SeriesEquipment Shutoff Valve GA5010 Information Video111604-01L Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace