Desa LMFP33PR(A) installation manual Parts List

Page 31

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

KEY

 

PART NUMBER

 

 

 

NO.

LMFP33PR

LMFP33PRA

LMFP33NR

LMFP33NRA

DESCRIPTION

QTY.

1a

111625-03

109072-01

111625-03

109072-01

Middle Log

1

1b

111625-04

109073-01

111625-04

109073-01

Rear Log

1

1c

111625-01

109074-01

111625-01

109074-01

Front Log

1

1d

111625-07

____

111625-07

____

Left Crossover Log

1

 

 

1e

111625-05

109075-01

111625-05

109075-01

Right Crossover Log

1

2

103778-01

103778-01

103779-01

103779-01

ODS Pilot

1

3

098249-01

098249-01

098249-01

098249-01

ODS Nut

2

4

099387-09

099387-09

099387-07

099387-07

Pilot Tube

1

5

104229-03

104229-03

111331-13

111331-13

Burner Outlet Tube

1

6

111124 -01

111124-01

111124-01

111124-01

Burner Retainer Spring

1

7

099056-31

099056-31

099056-26

099056-26

Burner Orifice Injector

1

8

102772-01

102772-01

102772-01

102772-01

Burner

2

9

M11084-38

M11084-38

M11084-38

M11084-38

Screw, #8-16 x .38

4

10

104236-01CK

104236-01CK

104236-01CK

104236-01CK

Painted Base Assy

1

11

M12461-26

M12461-26

M12461-26

M12461-26

Screw, #10-32 x .38

4

12

**

**

**

**

Firebox Bottom

1

13

M50104-02

M50104-02

M50104-02

M50104-02

Bushing

1

14

098265-02

098265-02

098265-02

098265-02

Elbow, Male

1

15

103782-01

103782-01

103782-01

103782-01

Valve Bracket

1

16

111440-04

111440-04

111440-03

111440-03

Gas Valve, Remote

1

17

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

1

18

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor

1

19

098304-01

098304-01

098304-01

098304-01

Screw

7

20

111442-02

111442-02

111442-02

111442-02

Digital Display Remote

 

 

 

 

 

 

Control

1

21

111441-02

111441-02

111441-02

111441-02

Proflame Receiver

1

22

104241-01

104241-01

104241-01

104241-01

Remote Switch Bracket

1

23

097809-02

097809-02

097809-02

097809-02

Male Connector

1

24

101628-03

101628-03

101628-03

101628-03

Flexible Connector (Hose)

1

25

M11084-26

M11084-26

M11084-26

M11084-26

Screw, #10-16 x .38

4

26

901063-01

901063-01

901063-01

901063-01

3/8" Flare x 1/2" NPT

1

27

____

____

099918-02

099918-02

Pilot Regulator

 

 

 

 

 

____

____

 

 

(Natural Only)

1

28

099387-07

099387-07

Pilot Tube

 

 

 

 

 

 

 

 

 

(Valve to Regulator)

1

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE

— NOT SHOWN

 

 

097555-01

097555-01

097555-01

097555-01

Caution Decal

1

 

 

 

 

 

 

 

** Not a field replaceable part.

111604-01L

www.desatech.com

31

Image 31
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Log Base AssemblyAIR for Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationElectrical Hookup Example Installing HoodInstalling Cabinet Mantel Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationInstalling Shield to Support Mantel Clearances for Built-In InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationPropane/LP Natural GasRemoving Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing LogsModels LMFP33PR and LMFP33NR Middle Models LMFP33PRA and LMFP33NRAInstalling Battery into Remote Installing Batteries in ReceiverOperating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To ApplianceHAND-HELD Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesPilot AIR Inlet Hole Burner Injector HolderLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, See Cleaning and Mainte Statement above Gas leak. See WarningReplacement Parts SpecificationsWiring Diagram Service Hints Technical ServiceModels LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA Shown Illustrated Parts BreakdownParts List Firebox LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA KEY Part Number Description QTY Information Video AccessoriesBlower Accessory GA3750A and GA3650TB Series Equipment Shutoff Valve GA5010111604-01L Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace