SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 24.

8.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventilation, page 5. If fireplace keeps shutting off, see Troubleshooting, page 25.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call

a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servic- ing. Only a qualified service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (propane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT

IDENTIFICATION

4-Piece Log Set (A Models shown)

Control

 

Knob

 

Piezo

 

Ignitor

Remote

Remote Control

Receiver

 

Figure 1 - Log Base Assembly

Top Louver Top Outer Casing

Blower

Assembly

Assembly

Firebox

(Optional)

 

Hood

 

Firebox

 

Support

 

Screen

Assembly

Bottom Louver Assembly

Figure 2 - Fireplace (LMFP33PR Shown)

4

www.desatech.com

111604-01L

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Log Base Assembly Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationElectrical Hookup Installing Hood ExampleConventional Fireplace Installation Installing Cabinet MantelBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelMantel Clearances for Built-In Installation Installing Shield to SupportInstalling GAS Piping to Fireplace Location Installation Items NeededNatural Gas Propane/LPConnecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing LogsModels LMFP33PR and LMFP33NR Models LMFP33PRA and LMFP33NRA MiddleInstalling Batteries in Receiver Installing Battery into RemoteOperating Heater For Your Safety Read Before LightingLighting Instructions Procedure To Turn OFF GASTo Appliance Manual LightingHAND-HELD Remote Operation Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerPilot AIR Inlet Hole Burner Injector HolderLogs Troubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Gas leak. See Warning Statement aboveSpecifications Wiring Diagram Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Models LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA ShownParts List Firebox LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA KEY Part Number Description QTY Accessories Blower Accessory GA3750A and GA3650TB SeriesEquipment Shutoff Valve GA5010 Information Video111604-01L Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace