OPERATING HEATER

Continued

1.STOP! Read the safety information on page 20.

2.Make sure equipment shutoff valve is fully open.

3.Set remote selector switch in the AUTO position (see Figure 35).

4.Press in and turn control knob clockwise to the OFF position (see Figure 35).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 20. If you donʼt smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 35).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

Ignitor Button

Control Knob

AUTO MAN

Remote Selector

Switch

Figure 35 - Remote Selector Switch, Control Knob and Ignitor Button

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Press the on/off key on the remote control to turn on appliance main burner. Wait at least 5 seconds before setting desired flame height.

11.Press the up or down key until the small triangle is to the left of large flame icon at the top of LCD display (see Figure 38, page 22). Press the left or right key to set the desired flame height.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Pilot Burner

Ignitor

 

Electrode

Figure 36 - Pilot (Propane/LP)

Pilot Burner

Ignitor

 

 

Electrode

Figure 37 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

 

Press on/off key on remote control and turn

control knob clockwise

to the OFF posi-

tion (see Figure 35).

 

Shutting Off Burners Only (pilot stays lit)

Press the on/off key on remote control or turn

control knob clockwise

to the PILOT

position.

 

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 7 under Lighting Instructions, column 1.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through

11 under Lighting Instructions.

111604-01L

www.desatech.com

21

Image 21
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Log Base AssemblyLocal Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeElectrical Hookup Example Installing HoodInstalling Cabinet Mantel Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationInstalling Shield to Support Mantel Clearances for Built-In InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationPropane/LP Natural GasRemoving Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaTest Pressures In Excess Of 1/2 Psig 3.5 kPa Installing Logs Pressure Testing Fireplace Gas ConnectionsModels LMFP33PR and LMFP33NR Middle Models LMFP33PRA and LMFP33NRAInstalling Battery into Remote Installing Batteries in ReceiverFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS ProcedureTo Appliance Manual LightingHAND-HELD Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerBurner Injector Holder Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, See Cleaning and Mainte Statement above Gas leak. See WarningWiring Diagram Service Hints SpecificationsTechnical Service Replacement PartsModels LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA Shown Illustrated Parts BreakdownParts List Firebox LMFP33PR, LMFP33PRA, LMFP33NR and LMFP33NRA KEY Part Number Description QTY Blower Accessory GA3750A and GA3650TB Series AccessoriesEquipment Shutoff Valve GA5010 Information Video111604-01L Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace