OPERATING HEATER
Continued
1.STOP! Read the safety information on page 20.
2.Make sure equipment shutoff valve is fully open.
3.Set remote selector switch in the AUTO position (see Figure 35).
4.Press in and turn control knob clockwise to the OFF position (see Figure 35).
5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 20. If you donʼt smell gas, go to the next step.
6.Press in and turn control knob counter-
clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 35).
Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 through 8.
Ignitor Button
Control Knob | AUTO MAN |
Remote Selector
Switch
Figure 35 - Remote Selector Switch, Control Knob and Ignitor Button
9.Slightly push in and turn control knob coun-
terclockwise to the ON position.
10.Press the on/off key on the remote control to turn on appliance main burner. Wait at least 5 seconds before setting desired flame height.
11.Press the up or down key until the small triangle is to the left of large flame icon at the top of LCD display (see Figure 38, page 22). Press the left or right key to set the desired flame height.
CAUTION: Do not try to ad- | |
just heating levels by using the | |
equipment shutoff valve. | |
Pilot Burner | Ignitor |
| Electrode |
Figure 36 - Pilot (Propane/LP) | |
Pilot Burner | Ignitor |
| |
| Electrode |
Figure 37 - Pilot (Natural)
TO TURN OFF GAS | |
TO APPLIANCE | |
Shutting Off Heater |
|
Press on/off key on remote control and turn | |
control knob clockwise | to the OFF posi- |
tion (see Figure 35). |
|
Shutting Off Burners Only (pilot stays lit) | |
Press the on/off key on remote control or turn | |
control knob clockwise | to the PILOT |
position. |
|
MANUAL LIGHTING | |
PROCEDURE |
1.Follow steps 1 through 7 under Lighting Instructions, column 1.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through
11 under Lighting Instructions.