Desa VTGF33PRB, VTGF33NRB Electrical Connections for Power Cord, Relocating Wall Switch Assembly

Page 10

INSTALLATION

Continued

ELECTRICAL CONNECTIONS FOR POWER CORD

This fireplace operates on 120 VAC, 60 Hz power. An electrical power cord is supplied with this unit.

For Mantel Installation

1.Determine from which side of the fireplace the power cord will exit. Locate the 1.5" diameter hole near the center of floor support bracket on appropriate side of lower cavity (see Figure 7).

2.Locate power cord. Remove wire tie or tape holding plug end of power cord.

3.Power cord has 2 plastic hole bushings threaded onto it. Route cordʼs 3-prong plug through the 1.5" diameter hole in appropriate floor support bracket.

4.Push first plastic bushing completely through hole. Squeeze bushing as needed to do this.

5.Install the second plastic bushing into the hole in the floor support bracket by snapping into place.

6.Route the 3-prong plug through the 1.5" hole in fireplace outer casing.

7.Install the first plastic bushing into this hole by snapping into place.

8.After you have connected to gas supply and checked your gas connections (see pages 14 and 15), plug power cord into any convenient 3- prong grounded wall receptacle near fireplace.

Hole in Floor

Hole in Outer

Support Bracket

Casing

Bushings

Power Cord

Figure 7 - Routing Power Cord

For Recessed Installation

If an outlet is not installed in fireplace, install

model GA3555 - Outlet Kit with Cover. This

kit will supply a convenient 3-prong grounded

electrical outlet for power. Refer to installation

manual provided with this optional accessory for

instructions on wiring. Note: A qualified installer

must make all electrical connections.

RELOCATING WALL SWITCH ASSEMBLY

Note: The decorative wall switch plate supplied is white. The wall switch plate may be painted to match your decor.

The push-button switch and decorative wall plate assembly supplied with your fireplace is pre-mounted at the factory in the lower cavity of the fireplace. You may relocate this wall switch assembly to a more convenient location such as the side of your mantel or directly onto the wall near the fireplace. To mount the wall switch assembly, you must first cut openings in the mantel or wall where the switch will be located.

Note: If you choose to relocate the wall switch as- sembly, do so before final installation into a mantel or recessing into a wall. If you are installing an optional blower accessory, install it at the same time you relocate the wall switch assembly.

CAUTION: The wall switch assembly must never be mount- ed directly above the fireplace where heat may damage it. If you relocate wall switch assembly from lower fireplace cavity, it must be mounted either on side wall of mantel or on wall to side of fireplace.

For Recessed Installation If fireplace is to be recessed into a wall (see Built-In Fireplace Installation, page 17), we recommend mounting wall switch assembly to left side of fireplace. The wall switch assembly should be mounted approximately 12" from left edge of fireplace, and less than 60" from the floor. IMPORTANT: Do not locate wall switch assembly directly in front of wall stud - there must be room behind wall board for wires from switch. If you choose to locate wall switch assembly to right side of fireplace, the length of the cord restricts you to less than 6" from right edge of fireplace and less than 48" from floor.

10

www.desatech.com

113134-01B

Image 10
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Unpacking Product FeaturesLocal Codes AIR for Combustion VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined Space and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Clearances Electrical HookupRemoving Fireplace Screen and Floor Assembly Installation SequenceMinimum 16 inches from Side Wall For Mantel Installation Electrical Connections for Power CordRelocating Wall Switch Assembly For Recessed InstallationRemove wall switch assembly from bracket Mounting Wall Switch Assembly to Wall for Recessed FireplaceOpening in Wall or Mantel Wall Wall Switch Assembly Screws Mounting Wall Switch Assembly to Side of MantelInstalling GAS Piping to Fireplace Location Installation Items NeededNatural Connecting Fireplace to GAS SupplyAssembly, Check all gas connections for leaks. SeeTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Conventional Fireplace Installation Break off nailing flanges see with hammer or pliersBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelAttaching Fireplace to Wall Studs Installing Hood Assembling Perimeter TrimInstalling Logs Installing Log #2 Right Log #3 LeftFor Your Safety Read Before Lighting Installing Battery Into RemoteInstalling Screen Operating FireplaceUsing Hand-Held Wireless Remote Control Using Supplied Wall Switch AssemblyNormal Lighting Instructions Shutting Off Heater Wireless Remote Control Manual Lighting Instructions for Electrical Power OutageShutting Off Heater Wall Switch To Turn OFF GAS To ApplianceOperating FAN Inspecting BurnersOptional Blower Operation Pilot Flame PatternBurner Flame Patterns Inspected yearly by a qualified service personYou could damage the pilot assembly Burner Injector HoldersSpecifications Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyOn windows Tilation air Not enough air Check burner for dirt OperationGas regulator defective Nance, Replace regulator Turning control knob toAssembly Clean ODS/pilot seeProblem could be caused by EnoughGas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints Parts Under WarrantyIllustrated Parts Breakdown Parts List KEY Part Number Description QTYFireplace Models VTGF33NRB and VTGF33PRB 100639-01 104356-02 Not a field replacement part Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseFire Crackle CF6-A Extruded Louver KIT Receiver and HAND-HELD Remote Control KIT Ghrcb Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbFirebox Brick Liner G8005 Templates Diameter Holes Diameter 2 HolesThis page Intentionally Left Blank Wiring Diagram 113134-01B 113134-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

VTGF33NRB, VTGF33PRB specifications

Desa VTGF33PRB and VTGF33NRB are advanced heating solutions that combine innovative technology and design for optimal performance and user convenience. These models are well-suited for residential and commercial applications, providing efficient heating while enhancing the overall aesthetic of any space.

One of the main features of the VTGF33PRB and VTGF33NRB is their high-efficiency ratings, which allow them to deliver effective heating with minimal energy consumption. This efficiency not only helps users save on energy bills, but it also makes these models environmentally friendly, aligning with modern sustainability goals.

Both models utilize advanced infrared heating technology, which generates heat by directly warming objects and people in the room rather than heating the air. This results in a more comfortable and even distribution of warmth, providing immediate relief from cold temperatures. The infrared heating method is particularly beneficial in large or drafty spaces, as it can significantly reduce heating times and energy usage.

In terms of design, the VTGF33PRB features a sleek, modern appearance that can easily complement any décor. Its robust construction ensures durability, making it suitable for long-term usage. The VTGF33NRB, on the other hand, offers a more traditional aesthetic, perfect for those who prefer classic designs. Both models are user-friendly, designed with intuitive controls that allow for easy operation and temperature adjustments.

Another noteworthy characteristic of the Desa VTGF33 series is their safety features. Each unit is equipped with advanced safety mechanisms, including tip-over protection, overheat shut-off, and a sturdy base to prevent accidents. These safety features provide peace of mind for users, especially in households with children or pets.

The VTGF33PRB and VTGF33NRB also incorporate quiet operation technology, ensuring that heating is achieved without disruptive noise. This makes them ideal for use in bedrooms, offices, or any space where tranquility is desired.

Overall, the Desa VTGF33PRB and VTGF33NRB are exemplary models that showcase the harmonious blend of efficiency, safety, and design. Their advanced features and technologies make them reliable choices for anyone looking to enhance their heating solutions while maintaining comfort and style. With their commitment to quality and innovation, Desa continues to lead the way in the heating industry.