Desa VTGF33PRB, VTGF33NRB Opening in Wall or Mantel Wall Wall Switch Assembly Screws

Page 12

INSTALLATION

Continued

11.Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.

12.From inside the recessed opening for the fireplace, carefully pass wall switch assembly through the rectangular opening to the outside of the wall.

13.Using wall anchors supplied in hardware pack- age, fold wall anchor as shown in Figure 11.

14.Insert wall anchor, wings first, into hole. Tap anchor flush to wall.

15.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. See Figure 12. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick), do not pop open wings.

16.Position wall switch assembly vertically over wall openings with decal lettering upright (see Figure 13).

Figure 11 - Folding Anchor

Figure 12 - Popping Open Anchor Wings

for Thin Walls

Opening in Wall or Mantel Wall

Wall Switch

Assembly

Screws

17.Insert mounting screws, removed in step 2 of Relocating Wall Switch Assembly on pages 10 and 11, through holes in wall plate and into wall anchors.

18.Tighten screws until wall plate is firmly at- tached to wall. Do not overtighten.

Mounting Wall Switch Assembly to Side of Mantel

7.Create three openings in the mantel wall ac- cording to Template 2, page 39. This is best done by making a pattern to work with on the mantel. Carefully cut page 39 from manual and tape paper template vertically onto mantel wall at preferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leaving a mark on the wall. Do the same at centers of the four circles near the corners of the rectangle.

8.Remove paper template from mantel wall.

9.Drill 1/8" pilot holes at each mark for top and bottom screw holes. Drill 3/8" holes at each mark for centers of four circles near corners of rectangle.

10.Using a straight edge and pencil, connect the outer edges of the 4 holes for the rectangle (see Figure 10, page 11). This will give you cutting lines for the rectangle you will cut in the mantel wall.

11.Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.

12.Carefully pass wall switch assembly through rectangular opening from inside mantel (see Figure 13).

13.Position wall switch assembly vertically over opening with decal lettering upright. Make sure wires freely pass through wall without binding. Align holes in wall plate with 1/8” pilot holes in mantel wall.

14.Drive mounting screws, removed in step 2 of Relocating Wall Switch Assembly on pages 10 and 11, through wall plate holes and into pilot holes in mantel wall.

15.Tighten screws until wall switch assembly is firmly attached to mantel. Do not over- tighten.

Figure 13 - Securing Wall Switch

Assembly

12

www.desatech.com

113134-01B

Image 12
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Product Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ClearancesCheck GAS Type Electrical HookupInstallation Sequence Removing Fireplace Screen and Floor AssemblyMinimum 16 inches from Side Wall Electrical Connections for Power Cord Relocating Wall Switch AssemblyFor Mantel Installation For Recessed InstallationRemove wall switch assembly from bracket Mounting Wall Switch Assembly to Wall for Recessed FireplaceOpening in Wall or Mantel Wall Wall Switch Assembly Screws Mounting Wall Switch Assembly to Side of MantelInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Assembly,Natural Check all gas connections for leaks. SeeChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaTest Pressures In Excess Of 1/2 Psig 3.5 kPa Conventional Fireplace Installation Break off nailing flanges see with hammer or pliersBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelAttaching Fireplace to Wall Studs Installing Hood Assembling Perimeter TrimInstalling Logs Installing Log #2 Right Log #3 LeftInstalling Battery Into Remote Installing ScreenFor Your Safety Read Before Lighting Operating FireplaceUsing Supplied Wall Switch Assembly Using Hand-Held Wireless Remote ControlNormal Lighting Instructions Manual Lighting Instructions for Electrical Power Outage Shutting Off Heater Wall SwitchShutting Off Heater Wireless Remote Control To Turn OFF GAS To ApplianceInspecting Burners Optional Blower OperationOperating FAN Pilot Flame PatternInspected yearly by a qualified service person You could damage the pilot assemblyBurner Flame Patterns Burner Injector HoldersCleaning Maintenance SpecificationsLogs Troubleshooting Observed Problem Possible Cause RemedyNot enough air Check burner for dirt Operation Gas regulator defective Nance, Replace regulatorOn windows Tilation air Turning control knob toClean ODS/pilot see Problem could be caused byAssembly EnoughGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List KEY Part Number Description QTYFireplace Models VTGF33NRB and VTGF33PRB 100639-01 104356-02 Not a field replacement part Accessories Cabinet Mantel and Full Hearth Base Laminate Trim for Hearth or MantelFire Crackle CF6-A Extruded Louver KIT Receiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbFirebox Brick Liner G8005 Templates Diameter Holes Diameter 2 HolesThis page Intentionally Left Blank Wiring Diagram 113134-01B 113134-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

VTGF33NRB, VTGF33PRB specifications

Desa VTGF33PRB and VTGF33NRB are advanced heating solutions that combine innovative technology and design for optimal performance and user convenience. These models are well-suited for residential and commercial applications, providing efficient heating while enhancing the overall aesthetic of any space.

One of the main features of the VTGF33PRB and VTGF33NRB is their high-efficiency ratings, which allow them to deliver effective heating with minimal energy consumption. This efficiency not only helps users save on energy bills, but it also makes these models environmentally friendly, aligning with modern sustainability goals.

Both models utilize advanced infrared heating technology, which generates heat by directly warming objects and people in the room rather than heating the air. This results in a more comfortable and even distribution of warmth, providing immediate relief from cold temperatures. The infrared heating method is particularly beneficial in large or drafty spaces, as it can significantly reduce heating times and energy usage.

In terms of design, the VTGF33PRB features a sleek, modern appearance that can easily complement any décor. Its robust construction ensures durability, making it suitable for long-term usage. The VTGF33NRB, on the other hand, offers a more traditional aesthetic, perfect for those who prefer classic designs. Both models are user-friendly, designed with intuitive controls that allow for easy operation and temperature adjustments.

Another noteworthy characteristic of the Desa VTGF33 series is their safety features. Each unit is equipped with advanced safety mechanisms, including tip-over protection, overheat shut-off, and a sturdy base to prevent accidents. These safety features provide peace of mind for users, especially in households with children or pets.

The VTGF33PRB and VTGF33NRB also incorporate quiet operation technology, ensuring that heating is achieved without disruptive noise. This makes them ideal for use in bedrooms, offices, or any space where tranquility is desired.

Overall, the Desa VTGF33PRB and VTGF33NRB are exemplary models that showcase the harmonious blend of efficiency, safety, and design. Their advanced features and technologies make them reliable choices for anyone looking to enhance their heating solutions while maintaining comfort and style. With their commitment to quality and innovation, Desa continues to lead the way in the heating industry.