Desa VTGF33PRB, VTGF33NRB installation manual Installing Logs, Installing Log #2 Right Log #3 Left

Page 20

INSTALLATION

Continued

INSTALLING LOGS

WARNING:Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation andperiodicallythereafter,check to ensure that no yellow flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. Ifso,repositionlogsaccordingto theloginstallationinstructionsin this manual. Yellow flames con- tacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs sup- plied with heater. Before installing logs, make sure log alignment screws are in place and straight.

1.Place log #1 (ember bed) onto base over log alignment screws to the left of front burner and behind middle burner. Log #1 will sit on top of front and middle burners (see Figure 31).

2.Place log #2 to right of log #1 and onto log alignment screw as shown in Figure 32. Log #2 will wrap around right end of rear burner.

3.Place log #3 on left side of base and onto alignment screw to right of rear burner (see Figure 32). Log #3 will wrap around left end of rear burner.

4.Place log #4 onto two alignment screws to rear of base (see Figure 33).

5.Locate hole on bottom of log #5 and place over pin on log #2. Log #5 will rest on back of log #1 (ember bed). See Figure 34.

6.Place log #6 onto two pins on log #1 (ember bed) and rest back of log #6 on back log #4 (see Figure 34).

Log #3

Log #2

Log #1

Figure 32 - Installing Log #2 (Right) and

Log #3 (Left)

Log #4

Log #3

Log #2

Log #1

Figure 33 - Installing Log #4

Log #6

 

Log #5

Log #3

Log #4

 

 

Log #2

 

Log #1

Figure 31 - Installing Log #1 (Ember Bed) Figure 34 - Installing Log #5 and Log #6

20

www.desatech.com

113134-01B

Image 20
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Product Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ClearancesCheck GAS Type Electrical HookupMinimum 16 inches from Side Wall Installation SequenceRemoving Fireplace Screen and Floor Assembly Electrical Connections for Power Cord Relocating Wall Switch AssemblyFor Mantel Installation For Recessed InstallationRemove wall switch assembly from bracket Mounting Wall Switch Assembly to Wall for Recessed FireplaceOpening in Wall or Mantel Wall Wall Switch Assembly Screws Mounting Wall Switch Assembly to Side of MantelInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Assembly,Natural Check all gas connections for leaks. SeeTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Conventional Fireplace Installation Break off nailing flanges see with hammer or pliersBUILT-IN Fireplace Installation Inserting Fireplace Into Cabinet MantelAttaching Fireplace to Wall Studs Installing Hood Assembling Perimeter TrimInstalling Logs Installing Log #2 Right Log #3 LeftInstalling Battery Into Remote Installing ScreenFor Your Safety Read Before Lighting Operating FireplaceNormal Lighting Instructions Using Supplied Wall Switch AssemblyUsing Hand-Held Wireless Remote Control Manual Lighting Instructions for Electrical Power Outage Shutting Off Heater Wall SwitchShutting Off Heater Wireless Remote Control To Turn OFF GAS To ApplianceInspecting Burners Optional Blower OperationOperating FAN Pilot Flame PatternInspected yearly by a qualified service person You could damage the pilot assemblyBurner Flame Patterns Burner Injector HoldersLogs Cleaning MaintenanceSpecifications Troubleshooting Observed Problem Possible Cause RemedyNot enough air Check burner for dirt Operation Gas regulator defective Nance, Replace regulatorOn windows Tilation air Turning control knob toClean ODS/pilot see Problem could be caused byAssembly EnoughGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List KEY Part Number Description QTYFireplace Models VTGF33NRB and VTGF33PRB 100639-01 104356-02 Not a field replacement part Accessories Fire Crackle CF6-A Extruded Louver KIT Cabinet Mantel and Full Hearth BaseLaminate Trim for Hearth or Mantel Firebox Brick Liner G8005 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb Templates Diameter Holes Diameter 2 HolesThis page Intentionally Left Blank Wiring Diagram 113134-01B 113134-01B Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

VTGF33NRB, VTGF33PRB specifications

Desa VTGF33PRB and VTGF33NRB are advanced heating solutions that combine innovative technology and design for optimal performance and user convenience. These models are well-suited for residential and commercial applications, providing efficient heating while enhancing the overall aesthetic of any space.

One of the main features of the VTGF33PRB and VTGF33NRB is their high-efficiency ratings, which allow them to deliver effective heating with minimal energy consumption. This efficiency not only helps users save on energy bills, but it also makes these models environmentally friendly, aligning with modern sustainability goals.

Both models utilize advanced infrared heating technology, which generates heat by directly warming objects and people in the room rather than heating the air. This results in a more comfortable and even distribution of warmth, providing immediate relief from cold temperatures. The infrared heating method is particularly beneficial in large or drafty spaces, as it can significantly reduce heating times and energy usage.

In terms of design, the VTGF33PRB features a sleek, modern appearance that can easily complement any décor. Its robust construction ensures durability, making it suitable for long-term usage. The VTGF33NRB, on the other hand, offers a more traditional aesthetic, perfect for those who prefer classic designs. Both models are user-friendly, designed with intuitive controls that allow for easy operation and temperature adjustments.

Another noteworthy characteristic of the Desa VTGF33 series is their safety features. Each unit is equipped with advanced safety mechanisms, including tip-over protection, overheat shut-off, and a sturdy base to prevent accidents. These safety features provide peace of mind for users, especially in households with children or pets.

The VTGF33PRB and VTGF33NRB also incorporate quiet operation technology, ensuring that heating is achieved without disruptive noise. This makes them ideal for use in bedrooms, offices, or any space where tranquility is desired.

Overall, the Desa VTGF33PRB and VTGF33NRB are exemplary models that showcase the harmonious blend of efficiency, safety, and design. Their advanced features and technologies make them reliable choices for anyone looking to enhance their heating solutions while maintaining comfort and style. With their commitment to quality and innovation, Desa continues to lead the way in the heating industry.