LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

CAUTION: Do not remove the dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

1.With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Remove packing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.

2.Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.

3.Remove protective packaging applied to logs, log base assembly, and fireplace.

4.Remove fireplace hood from carton insert.

5.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. When used without the optional blower, the fireplace requires no electricity making it ideal for emergency backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot system shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.

WIRELESS REMOTE CONTROL

This fireplace features an infrared wireless remote control. This control system can be used to auto- matically light the pilot and adjust the burner flame height at the push of a button.

WIRED WALL-MOUNTED REMOTE CONTROL

This fireplace features a two-button wall switch assembly with glowing LEDʼs. The wall switch performs the same functions as the wireless hand- held remote control with the added feature of LEDʼs for visual feedback of operation and status.

BLOWER ASSEMBLY

This fireplace includes a blower assembly. The blower operates thermostatically. The blower circu- lates heated air from the fireplace into the room.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall not be installed in a confined spaceorunusuallytightconstruc- tionunlessprovisionsareprovid- ed for adequate combustion and ventilation air. Read the following instructionstoinsureproperfresh air for this and other fuel-burning appliances in your home.

Todayʼs homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

113134-01B

www.desatech.com

5

Image 5
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Local Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Clearances InstallationCheck GAS Type Electrical HookupMinimum 16 inches from Side Wall Installation SequenceRemoving Fireplace Screen and Floor Assembly Relocating Wall Switch Assembly Electrical Connections for Power CordFor Mantel Installation For Recessed InstallationMounting Wall Switch Assembly to Wall for Recessed Fireplace Remove wall switch assembly from bracketMounting Wall Switch Assembly to Side of Mantel Opening in Wall or Mantel Wall Wall Switch Assembly ScrewsInstallation Items Needed Installing GAS Piping to Fireplace LocationAssembly, Connecting Fireplace to GAS SupplyNatural Check all gas connections for leaks. SeeTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Break off nailing flanges see with hammer or pliers Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Assembling Perimeter Trim Installing HoodInstalling Log #2 Right Log #3 Left Installing LogsInstalling Screen Installing Battery Into RemoteFor Your Safety Read Before Lighting Operating FireplaceNormal Lighting Instructions Using Supplied Wall Switch AssemblyUsing Hand-Held Wireless Remote Control Shutting Off Heater Wall Switch Manual Lighting Instructions for Electrical Power OutageShutting Off Heater Wireless Remote Control To Turn OFF GAS To ApplianceOptional Blower Operation Inspecting BurnersOperating FAN Pilot Flame PatternYou could damage the pilot assembly Inspected yearly by a qualified service personBurner Flame Patterns Burner Injector HoldersLogs Cleaning MaintenanceSpecifications Observed Problem Possible Cause Remedy TroubleshootingGas regulator defective Nance, Replace regulator Not enough air Check burner for dirt OperationOn windows Tilation air Turning control knob toProblem could be caused by Clean ODS/pilot seeAssembly EnoughStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListFireplace Models VTGF33NRB and VTGF33PRB 100639-01 104356-02 Not a field replacement part Accessories Fire Crackle CF6-A Extruded Louver KIT Cabinet Mantel and Full Hearth BaseLaminate Trim for Hearth or Mantel Firebox Brick Liner G8005 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb Diameter Holes Diameter 2 Holes TemplatesThis page Intentionally Left Blank Wiring Diagram 113134-01B 113134-01B Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

VTGF33NRB, VTGF33PRB specifications

Desa VTGF33PRB and VTGF33NRB are advanced heating solutions that combine innovative technology and design for optimal performance and user convenience. These models are well-suited for residential and commercial applications, providing efficient heating while enhancing the overall aesthetic of any space.

One of the main features of the VTGF33PRB and VTGF33NRB is their high-efficiency ratings, which allow them to deliver effective heating with minimal energy consumption. This efficiency not only helps users save on energy bills, but it also makes these models environmentally friendly, aligning with modern sustainability goals.

Both models utilize advanced infrared heating technology, which generates heat by directly warming objects and people in the room rather than heating the air. This results in a more comfortable and even distribution of warmth, providing immediate relief from cold temperatures. The infrared heating method is particularly beneficial in large or drafty spaces, as it can significantly reduce heating times and energy usage.

In terms of design, the VTGF33PRB features a sleek, modern appearance that can easily complement any décor. Its robust construction ensures durability, making it suitable for long-term usage. The VTGF33NRB, on the other hand, offers a more traditional aesthetic, perfect for those who prefer classic designs. Both models are user-friendly, designed with intuitive controls that allow for easy operation and temperature adjustments.

Another noteworthy characteristic of the Desa VTGF33 series is their safety features. Each unit is equipped with advanced safety mechanisms, including tip-over protection, overheat shut-off, and a sturdy base to prevent accidents. These safety features provide peace of mind for users, especially in households with children or pets.

The VTGF33PRB and VTGF33NRB also incorporate quiet operation technology, ensuring that heating is achieved without disruptive noise. This makes them ideal for use in bedrooms, offices, or any space where tranquility is desired.

Overall, the Desa VTGF33PRB and VTGF33NRB are exemplary models that showcase the harmonious blend of efficiency, safety, and design. Their advanced features and technologies make them reliable choices for anyone looking to enhance their heating solutions while maintaining comfort and style. With their commitment to quality and innovation, Desa continues to lead the way in the heating industry.