Desa Tech CGEFP33PR installation manual OWNER’S Operation and Installation Manual

Page 1

UNVENTED (VENT-FREE)

PROPANE/LP GAS FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

CGEFP33PR

AND

EFP33PR

GAS FIREPLACE

WITH TOTAL

CONTROL

SYSTEM (TCS)

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

Shown with optional

cabinet mantel,

hearth base, and trim

accessories.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional infor- mation consult a qualified in- staller, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by state or local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Electrical HookupRemoval of Fireplace Screen and Floor Assembly Installation SequenceRelocating Wall Switch Lines and wiring when moving floor Mounting Wall Switch to Side of Mantel Installing Variable Speed Blower AccessoryOperating the Blower Installing Plastic Bushing for Power CordLower Rear Wall Firebox Blower Installing Thermostatic Blower AccessoryInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Checking GAS ConnectionsChecking Gas Joints Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing HoodInstalling Logs EFP33PR Installing Logs CGEFP33PRInstalling Battery Into Remote Installing ScreenUsing Supplied Wall Switch For Your Safety Read Before LightingUsing Hand-Held Wireless Remote Control Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting Instructions For Electrical Power OutageOptional Blower Operation Inspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement Parts SpecificationsService Hints Technical ServiceParts Dealers Illustrated Parts Breakdown Remote Control Fireplace EFP33PR and CGEFP33PR Parts ListFirebox KEY Part Number Description QTY Blower Accessory GA3750 Series and GA3650T Series AccessoriesCorner Mantel Equipment Shutoff Valve GA5010Diameter Holes This page Intentionally Left Blank 107570 Warranty Information