Desa Tech installation manual Installing Logs CGEFP33PR, Installing Logs EFP33PR

Page 19

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING LOGS (CGEFP33PR)

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 40).

Back

Log (#1)

Hole in

Grate Base

Burner

Figure 40 - Installing Back Log (#1)

2.Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 41). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend.

3.Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 42).

4.Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the crossover log lines up with rectangular knobs on top of the middle and front logs (see Figure 43).

Middle Log (#2)

Tab

Cutout

Burner

“U” Bend

U-Shaped

Slot

Figure 41 - Installing Middle Log (#2)

Front Log (#3)

Recess

Post

Post

Figure 42 - Installing Front Log (#3)

Crossover

Log (#4)

Rectangular

Knobs

Figure 43 - Installing Crossover Log (#4)

INSTALLING LOGS (EFP33PR)

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the warning and instruction labels attached to the heater base as- sembly. These markings contain important warranty information.

WARNING: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

Continued

107570

19

For more information, visit www.desatech.com

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingElectrical Hookup InstallationInstallation Clearances Check GAS TypeRemoval of Fireplace Screen and Floor Assembly Installation SequenceRelocating Wall Switch Lines and wiring when moving floor Mounting Wall Switch to Side of Mantel Installing Variable Speed Blower AccessoryOperating the Blower Installing Plastic Bushing for Power CordLower Rear Wall Firebox Blower Installing Thermostatic Blower AccessoryInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking Gas Joints Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing HoodInstalling Logs EFP33PR Installing Logs CGEFP33PRInstalling Battery Into Remote Installing ScreenOperating Fireplace For Your Safety Read Before LightingUsing Supplied Wall Switch Using Hand-Held Wireless Remote ControlTo Turn OFF GAS To Appliance Manual Lighting Instructions For Electrical Power OutageOptional Blower Operation Inspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Technical Service SpecificationsReplacement Parts Service HintsParts Dealers Illustrated Parts Breakdown Remote Control Fireplace EFP33PR and CGEFP33PR Parts ListFirebox KEY Part Number Description QTY Equipment Shutoff Valve GA5010 AccessoriesBlower Accessory GA3750 Series and GA3650T Series Corner MantelDiameter Holes This page Intentionally Left Blank 107570 Warranty Information