Desa Tech EFP33PR BUILT-IN Fireplace Installation, Inserting Fireplace Into Cabinet Mantel

Page 17

OWNER’S MANUAL

INSTALLATION

Continued

10.Route electrical cord(s) through access holes in either side of fireplace with bushing. Plug electrical cord(s) into electrical outlet.

11.Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Re- move protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.

12.Check all gas connections for leaks. See Checking Gas Connections, page 15.

Figure 32 - Inserting Fireplace Into Cabinet Mantel

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 36, page 18. Follow the instructions below to install the fireplace in this manner.

 

Actual

 

Framing

 

 

 

 

Height

32 3/8"

 

33"

Front Width

34 5/

16

"

35 1/ "

 

 

 

2

Depth

16 11/16"

17 3/4"

1.Frame in rough opening. Use dimen- sions shown in Figure 33 for the rough opening. If installing in a corner, use dimensions shown in Figure 34 for the rough opening. The height is 33" which is the same as the wall opening above.

2.Install and properly ground GA3555, three-prong 120 volt electrical outlet, in fireplace. Follow instructions in- cluded in kit (see Accessories, page 34).

3.If not already completed, install gas pip- ing to fireplace location. This installa- tion includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 14.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Attach flexible gas line to gas supply. See Connecting Fireplace to Gas Sup- ply, page 15.

6.Plug electrical cord(s) into electrical outlet installed in step 2.

7.Carefully insert fireplace into rough opening.

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 35).

9.Check all gas connections for leaks. See Checking Gas Connections, page 15.

10.Install brass trim. See Assembling and Attaching Optional Brass Trim, page 18.

17 3/4"

33"

35 1/2"

Figure 33 - Rough Opening for Installing in Wall

39 3/8"

27 7/8"

35 1/2" 55 5/8"

Figure 34 - Rough Opening for Installing in Corner

Nails or

Wood

Screws

Nailing

Flanges

Figure 35 - Attaching Fireplace to Wall Studs

Continued

107570

17

For more information, visit www.desatech.com

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented PROPANE/LP GAS Fireplace Safety InformationUnpacking Product IdentificationLocal Codes AIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Electrical HookupRelocating Wall Switch Installation SequenceRemoval of Fireplace Screen and Floor Assembly Lines and wiring when moving floor Mounting Wall Switch to Side of Mantel Installing Variable Speed Blower AccessoryOperating the Blower Installing Plastic Bushing for Power CordLower Rear Wall Firebox Blower Installing Thermostatic Blower AccessoryInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Checking GAS ConnectionsChecking Gas Joints Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing HoodInstalling Logs EFP33PR Installing Logs CGEFP33PRInstalling Battery Into Remote Installing ScreenUsing Supplied Wall Switch For Your Safety Read Before LightingUsing Hand-Held Wireless Remote Control Operating FireplaceOptional Blower Operation Manual Lighting Instructions For Electrical Power OutageTo Turn OFF GAS To Appliance Inspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement Parts SpecificationsService Hints Technical ServiceParts Dealers Illustrated Parts Breakdown Remote Control Fireplace EFP33PR and CGEFP33PR Parts ListFirebox KEY Part Number Description QTY Blower Accessory GA3750 Series and GA3650T Series AccessoriesCorner Mantel Equipment Shutoff Valve GA5010Diameter Holes This page Intentionally Left Blank 107570 Warranty Information