Desa Tech CGEFP33PR Operating the Blower, Installing Plastic Bushing for Power Cord

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

8.Plug in blower power cord.

a.If your fireplace system is installed as a freestanding unit with an ac- cessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. In- stall 1 plastic bushing provided into the 1.5" hole in the floor support bracket on the exit side (see Figure 16). Install the second plastic bush- ing provided into the 1.5" hole in the outer casing through which the power cord will exit. Route power cord through both plastic bushings and plug the power cord into a prop- erly grounded 3-prong wall recep- tacle near the firebox.

b.If your fireplace system installation is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wiring the duplex outlet.

Note: A qualified installer must make all electrical connections.

9.Check to make sure that all electrical cords are completely clear of the blower wheel and that there are no other for- eign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing.

WARNING: Never touch the blower wheel while in operation.

10.Peel off backing paper and stick supplied wiring diagram decal near center of fire- box bottom (Figure 17).

11.If gas connections have been made and checked, replace fireplace floor assembly. Feed flexible gas supply line into fireplace base area while replac- ing fireplace floor assembly. Make sure the entire flexible gas line is in fireplace base area.

IMPORTANT: Do not pick up fire- place floor assembly by burners. This could damage burners. Only handle base by grates. Note: Be careful of all wires and components on underside of floor assembly.

12.Reattach fireplace floor assembly with screws removed in step 3 of Removing Fireplace Screen and Floor Assembly, page 8. Note: Discard the remaining hardware items. After assembly, make sure all wires are completely clear of blower wheel.

13.Install logs (see Installing Logs, pages 19 and 20) and fireplace screen (see In- stalling Fireplace Screen, page 20).

WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved with this heater may result in dam- age or personal injury.

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

Operating the Blower

Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire.

Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.

Right Floor

Plastic

Support

Bushing

Bracket

 

Figure 16 - Installing Plastic Bushing for Power Cord

WARNING: Never attempt to service heater while it is plugged in, operating, or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105° C wire or it’s equivalent.

WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause im- proper and dangerous operation. Verify proper opera- tion after servicing.

 

 

Variable

 

 

 

Fan Switch

 

 

 

Off

On

 

110/115

 

Black

Black

Blower

V.A.C.

Black

 

 

Motor

 

 

 

Black

 

Green

 

 

 

White

White

 

 

 

 

 

Wiring

120 Vac. 60 Hz. . 78 Amps

 

 

 

 

101584-05

Diagram

DESA International, Bowling Green, KY

Figure 17 - Location of Wiring Diagram Decal 3" from Blower

Continued

107570

11

For more information, visit www.desatech.com

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented PROPANE/LP GAS Fireplace Safety InformationUnpacking Product IdentificationLocal Codes AIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingElectrical Hookup InstallationInstallation Clearances Check GAS TypeRelocating Wall Switch Installation SequenceRemoval of Fireplace Screen and Floor Assembly Lines and wiring when moving floor Mounting Wall Switch to Side of Mantel Installing Variable Speed Blower AccessoryOperating the Blower Installing Plastic Bushing for Power CordLower Rear Wall Firebox Blower Installing Thermostatic Blower AccessoryInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking Gas Joints Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing HoodInstalling Logs EFP33PR Installing Logs CGEFP33PRInstalling Battery Into Remote Installing ScreenOperating Fireplace For Your Safety Read Before LightingUsing Supplied Wall Switch Using Hand-Held Wireless Remote ControlOptional Blower Operation Manual Lighting Instructions For Electrical Power OutageTo Turn OFF GAS To Appliance Inspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Technical Service SpecificationsReplacement Parts Service HintsParts Dealers Illustrated Parts Breakdown Remote Control Fireplace EFP33PR and CGEFP33PR Parts ListFirebox KEY Part Number Description QTY Equipment Shutoff Valve GA5010 AccessoriesBlower Accessory GA3750 Series and GA3650T Series Corner MantelDiameter Holes This page Intentionally Left Blank 107570 Warranty Information