Desa Tech CGEFP33PR installation manual Observed Problem Possible Cause Remedy

Page 25

OWNER’S MANUAL

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

 

pane/LP gas company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see pages 8 through 10)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 23) or replace burner orifice

 

 

 

 

 

 

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot (manual ignition mode)

 

tor cable

 

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

 

base panel

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

 

7.

Ignitor electrode positioned wrong

7.

Replace piezo ignitor and bracket

 

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition (manual

 

shutoff valve closed

 

shutoff valve

 

ignition mode)

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position full

 

 

 

 

 

counterclockwise

 

 

3.

Air in gas lines when installed

3.

Continue holding control knob in full

 

 

 

 

 

counterclockwise position. Repeat

 

 

 

 

 

igniting operation until air is removed

 

 

4.

ODS/pilot is clogged

4.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 23) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

5.

Gas regulator setting is not correct

5.

Replace gas regulator

 

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully turned counter-

1.

Turn control knob fully counterclock-

 

control knob is released (manual ignition

 

clockwise

 

wise

 

mode)

2.

Control knob not held long enough

2.

After ODS/pilot lights, hold control

 

 

 

 

 

knob for 30 seconds

 

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local propane/LP gas com-

 

 

 

which allows thermocouple to cool,

 

pany

 

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

the following:

 

Maintenance, page 23) or replace ODS/

 

 

 

A) Low gas pressure

 

pilot assembly

 

 

 

B) Dirty or partially clogged OD S/pilot

 

 

 

 

 

5.

Thermocouple connection loose at con-

 

 

 

 

 

 

trol valve

5.

Hand tighten until snug, then tighten

 

 

6.

Thermocouple damaged

 

1/4 turn more

 

 

7.

Control valve damaged

6.

Replace pilot assembly

 

 

 

 

7.

Replace control valve

 

B

 

www.desatech.com

 

Continued

 

 

 

 

 

 

 

107570

25

For more information, visit www.desatech.com

Image 25
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Electrical HookupRemoval of Fireplace Screen and Floor Assembly Installation SequenceRelocating Wall Switch Lines and wiring when moving floor Mounting Wall Switch to Side of Mantel Installing Variable Speed Blower AccessoryOperating the Blower Installing Plastic Bushing for Power CordLower Rear Wall Firebox Blower Installing Thermostatic Blower AccessoryInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Checking GAS ConnectionsChecking Gas Joints Conventional Fireplace InstallationInserting Fireplace Into Cabinet Mantel BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing HoodInstalling Logs EFP33PR Installing Logs CGEFP33PRInstalling Battery Into Remote Installing ScreenUsing Supplied Wall Switch For Your Safety Read Before LightingUsing Hand-Held Wireless Remote Control Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting Instructions For Electrical Power OutageOptional Blower Operation Inspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement Parts SpecificationsService Hints Technical ServiceParts Dealers Illustrated Parts Breakdown Remote Control Fireplace EFP33PR and CGEFP33PR Parts ListFirebox KEY Part Number Description QTY Blower Accessory GA3750 Series and GA3650T Series AccessoriesCorner Mantel Equipment Shutoff Valve GA5010Diameter Holes This page Intentionally Left Blank 107570 Warranty Information