UNVENTED PROPANE/LP GAS FIREPLACE
OPERATING
FIREPLACE
Continued
4.When pilot flame is lit, the thermo- couple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automati- cally light on high flame.
5.To lower flame, point remote control toward lower front of fireplace and push HI/LO button once.
Note: This fireplace does not have a
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater - Wall Switch
Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote Control
Point remote control toward lower front of fireplace and push both buttons at the same time.
MANUAL LIGHTING
INSTRUCTIONS
FOR ELECTRICAL
POWER OUTAGE
WARNING: You must operate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.
NOTICE: During initial operation of new heater, burning logs will give off a
Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light automatically.
1.Follow steps 1 through 3 under Nor- mal Lighting Instructions, page 21.
2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 52.
3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.
4.Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Fig- ure 51).
5.Turn the override handle fully coun-
terclockwise to the PILOT po- sition. The handle will not stop but will begin to slip when you have fully turned to the PILOT position.
6.While holding the valve handle in the PILOT position, press and release piezo ignitor button (see Figure 52). This will light the pilot. If needed, keep pressing ignitor button until pi- lot lights.
7.When pilot flame is lit, hold manual override handle until thermocouple heats (approximately 5 to 15 sec- onds). If pilot goes out, repeat pro- cess. If several attempts to light the pilot fail, contact a qualified service person or gas supplier for repairs.
Gas | Piezo |
| Manual Ignition | ||
| Bypass Switch | ||||
Valve | Ignitor |
| (Down is ON) | ||
HI/LO |
|
| IGNITION |
| |
|
|
| MANUAL |
| |
Button |
|
|
|
| |
|
|
| HI LO | ON OFF | |
Magnetic |
|
|
|
| |
Manual Override | LED | LED | |||
Handle | Wall | ||||
| ON/OFF |
| |||
|
|
| |||
| Switch | Button |
|
Figure 52 - Control Locations
8.When thermocouple is heated, re- lease override handle. The main burner will immediately light on high flame. Adjust flame size by turning override handle.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater When Manually Lit
Set manual ignition bypass switch on con- trol panel to OFF (automatic ignition position). This will cause the controls to shut down the fireplace.
OPTIONAL BLOWER
OPERATION
Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower right inside louver door.
The GA3650TA Series
Note for GA3650TA Series Only: If you are using GA3650TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will con- tinue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.
Follow installation instructions included with the blower accessory.
For more information, visit www.desatech.com | 22 | 107570 |