d)Unlatch the Spider Stopper Guards and remove. Figure 11.
Figure 11
e)Use an adjustable wrench to remove the thermocouple from the FlameCheck valve.
f)Remove the manifold bracket and unscrew the two thumb screws that hold the manifold to the cooking box. Pull the manifold and valve assembly out of the burners and carefully set it down. Figure 12.
View from behind cooking box
Thumb screws
Figure 12
g)Slide the burner assembly out from under the guide screw and washer in the corners of the cooking box. Figure 13.
Guide screw
Figure 13
h)Lift and twist the burner assembly slightly, to separate the crossover tube from the burners. Figure 14. Remove the burners from the cooking
box.
Crossover tube
Figure 14
i)To reinstall burners, reverse steps c) through h).
CAUTION: The burner openings must be positioned properly over the valve orifices. Figure 15a.
Check proper assembly before fastening manifold in place. Figure 15b.
(a)
Valve
Burner
(b)
Figure 15
35