TROUBLE SHOOTING:
To see trouble shooting or assembly videos, visit us at:
Problem | Possible Cause | Prevention/Cure | |
Burner will not light | LP gas tank valve is closed | Make sure regulator is securely attached to the LP gas tank, turn LP | |
|
| gas tank valve to “OPEN” | |
|
|
| |
| LP gas tank is low or empty | Check if LP gas tank is empty. If empty, replace or refill. | |
|
|
| |
| LP gas leak | 1. Turn LP gas tank valve to “CLOSED” | |
|
| 2. Wait 5 minutes for gas to clear | |
|
| 3. Follow “Leak Testing” in the owner’s manual | |
|
|
| |
| Coupling nut and regulator not fully connected | See section on “Connecting Hose and Regulator” | |
|
|
| |
| Obstruction of gas flow | 1. Clean burner assembly | |
|
| 2. Check for bent or kinked hose | |
|
|
| |
| Burner may not be properly seated | Reseat burner and valve. Refer to “Burner Assembly/Maintenance” | |
|
| instructions | |
|
|
| |
| Spider webs or insect nest in venturi | Clean venturi and burner assembly | |
|
|
| |
| Burner ports clogged or blocked | Clean burner ports | |
|
|
| |
| Battery needs to be changed | Replace the battery (follow assembly step for inserting battery) | |
|
|
| |
| Wires or electrode covered with cooking residue | Clean wire and/or electrode with rubbing alcohol | |
|
|
| |
| Electrode and burners are wet | Wipe dry with cloth | |
|
|
| |
| Electrode cracked or broken - sparks at crack | Replace electrode | |
|
|
| |
| Wire loose or disconnected | Reconnect wire or replace electrode/wire assembly | |
|
|
| |
| Wire is shorting (sparking) between ignitor and | Replace ignitor wire/electrode assembly | |
| electrode |
| |
|
|
| |
| Bad ignitor | Replace ignitor | |
|
|
| |
Grill does not get hot | Out of gas | Replace or refill LP gas tank | |
enough |
|
| |
Flow limiting device may have been activated | 1. Mini Reset: | ||
| |||
|
| a. Turn control knobs and LP gas tank valve to “OFF” | |
|
| b. Wait one minute and relight grill per “Lighting Instructions” | |
|
| 2. If flames are still too low, perform a Full Reset | |
|
| Full Reset: | |
|
| a. Turn control knobs and LP gas tank valve to “OFF” | |
|
| b. Disconnect regulator from propane tank | |
|
| c. Inspect LP cylinder rubber seal | |
|
| d. Wait 1 minute | |
|
| e. Reconnect regulator and perform “Leak Testing” on all | |
|
| connections. | |
|
| f. Light grill per “Lighting Instructions” | |
|
|
| |
Irregular flame pattern. | Burner ports are clogged or blacked | Clean burner ports | |
Flame does not run full |
|
| |
length of burner | Air shutter on burner needs adjustment | See section on “Burner Adjustment” | |
|
|
| |
Flame is yellow or orange | New burner may have residual manufacturing | Burn grill for 15 minutes on “HIGH” with the lid closed | |
| oils |
| |
|
|
| |
| Spider webs or insect nest in venturi | Clean venturi and burner assembly | |
|
|
| |
| Food residue, grease, etc. | Clean burner assembly | |
|
|
| |
| Poor alignment of valve to burner venturi | Make sure burner venturi is properly engaged with valve |
Air shutter on burner needs adjustment
See section on “Burner Adjustment”
16